Part Number Hot Search : 
SZ1A30 RD475M0 CD4033 55162 TSSOP 1058206 K40A06 74LV240N
Product Description
Full Text Search
 

To Download H7CX-AW-N Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 new product multifunction counter/tachometer h7cx-@ -n ultra-compact counter provides more complete functionality. basic features ? short body with depth of only 59 mm (for 12 to 24-vdc models with screw terminals). *1  better readability with character hei ght of 12 mm on 4-digit models and 10 mm on 6-digit models.  the present value displa y characters can be swit ched between red, green, and orange. *2 safety and reliability  new set value limit and c ounter functions have been added. other features  front panel can be changed to white or light gray. *3  models with two independent tachometer inputs have been added to the series. *1.for 100 to 240-vac models with screw terminals: 78 mm, models with sockets: 63.7 mm (case dimension). *2.the h7cx-a11 and h7cx-r11 have only red characters. *3.the front panel can be replaced with an optional front panel (except for tachometer-only models). features basic features ultra short body the body depth has been greatly r educed. helps in making thinner control panels. easier to read for better readability, the character height for the present value display is 12 mm on models with 4 di gits, the largest class in the industry. the wide viewing angle and brightness provide excellent visibility. the number of display segments has also been increased to make settings easier to understand, and the present value display can be switched between red, green, and orange so that output status can be seen from a distance. note: the display color can be switched on all models except for the h7cx-a11 and h7cx-r11. the easiest operation operation is simplified by the up/down key for each digit on 4-digit models and up key for each digit on 6-digit models. safety and reliability isolated power suppl y and input circuits power supply circuit and i nput circuits are isolated inside the counter/ tachometer. previous non-isolat ed counters had wiri ng restrictions and could be damaged if wired incorrec tly. the h7cx removes these worries. note: except 12 to 24-vdc models. set value limit you can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes. output counter the output counter counts the number of times the output turns on (alarms can be displayed and the count can be monitored in increments of 1,000 operations). this counter is useful in managing the service life of the counter/tachometer or the load. refer to safety precautions on page 52. 12 to 24-vdc models with screw terminals: 59 mm 100 to 240-vac models with screw terminals: 78 mm* models with sockets: 63.7 mm (case dimension) * power supply circuit and input circuits are isolated for safety and reliability. new models previous models 12 mm (actual size) model with 4 digits model with 6 digits 10 mm (actual size) (display example) new models previous models easy to read from the top, bottom, and sides! model with 4 digits model with 6 digits for 1,000 pieces no overflow setting the upper limit of the set value enables worry-free operation.
2 h7cx-@ -n other features the front color can be changed simply by replacing the front panel. the front panel can be replaced with an optional front panel (sold separately) with a different color to match the installation site. select from black, white, and light gray (except for models with tachometer function only). universal npn/pnp input dc 2-wire sensors can be connected for a wide range of input devices. waterproof, dust-proof structure (ul508 type 4x and ip66) worry-free application is possible in locations subject to water. note: when the y92s-29 waterp roof packing is used. key protection select from any of seven protection patterns. use the best one for the application. new functions many useful functions have bee n added, including a twin counter mode and many tachometer func tions to handle even more applications. new tachometer functions  control with two independent inputs (independent measurements, differential, absolute ratio, and error ratio)  peak/bottom hold function  output hysteresis setting  output off delay  switching the measurement method (pulse cycle/pulse width)  startup time  auto-zero time  averaging method/number of averaging times  amd-compatible mode model number structure model configuration *1. set the tachometer input mode from the function setting mode to switch to the tachometer function. white light gray black (standard) only the front panel can be replaced. h7cx series model h7cx-a-series multifunction preset coun ter h7cx-r-series digital tachometer classification preset counter preset counter/tachometer tachometer model h7cx-a @ -n h7cx-a4w @ -n h7cx-aw @ -n/-au @ -n h7cx-r11 @ -n h7cx-r11w @ -n function 1-stage preset counter yes yes yes no 2-stage preset counter no yes yes no total and preset counter yes yes yes no batch counter no yes yes no dual counter no yes yes no twin counter no yes yes no tachometer no no yes *1 yes tachometer input no no yes 1 input or 2 inputs (independent measurements, differential, absolute ratio value, and error ratio value) yes 1 input yes 2 inputs (independent measurement) only settings 1-stage 2-stage 1-stage external connections 11-pin socket screw terminals 11-pin socket display color of present value red red, green, or orange red display digits 4 or 6 digits 4 digits 6 digits 6 digits
h7cx- @ -n 3 model number legend (not all possible combinations of functions are available.) h7cx- @@@@@@ -n 123456 ordering information list of models note: 1. the functions that are provided depend on the model. check detailed specific ations before ordering. 2. refer to page page 37 and later for information on h7cx-r tachometers. type classification configuration external connections settings display digits outputs power supply voltage model h7cx-a series preset counter  1-stage preset counter  total and preset counter 11-pin socket 1-stage 4 digits contact output (spdt) 100 to 240 vac h7cx-a114-n transistor output (spst) h7cx-a114s-n contact output (spdt) 12 to 24 vdc/24 vac h7cx-a114d1-n 6 digits contact output (spdt) 100 to 240 vac h7cx-a11-n transistor output (spst) h7cx-a11s-n contact output (spdt) 12 to 24 vdc/24 vac h7cx-a11d1-n transistor output (spst) h7cx-a11sd1-n screw terminals 4 digits contact output (spdt) 100 to 240 vac h7cx-a4-n transistor output (spst) h7cx-a4s-n contact output (spdt) 12 to 24 vdc h7cx-a4d-n transistor output (spst) h7cx-a4sd-n 6 digits contact output (spdt) 100 to 240 vac h7cx-a-n transistor output (spst) h7cx-as-n contact output (spdt) 12 to 24 vdc h7cx-ad-n transistor output (spst) h7cx-asd-n  1-stage preset counter  2-stage preset counter  total and preset counter  batch counter  dual counter  twin counter 2-stage 4 digits contact output (spst + spdt) 100 to 240 vac h7cx-a4w-n transistor output (dpst) 12 to 24 vdc h7cx-a4wsd-n preset counter/ tachometer  1-stage preset counter  2-stage preset counter  total and preset counter  batch counter  dual counter  twin counter  tachometer 6 digits contact output (spst + spdt) 100 to 240 vac H7CX-AW-N transistor output (dpst) h7cx-aws-n contact output (spst + spdt) 12 to 24 vdc/24 vac h7cx-awd1-n transistor output (dpst) h7cx-awsd1-n 12 to 24 vdc h7cx-awsd-n contact output (spdt) + transistor output (spst) 100 to 240 vac h7cx-au-n contact output (spdt) + transistor output (spst) 12 to 24 vdc/24 vac h7cx-aud1-n transistor output (dpst) h7cx-ausd1-n h7cx-r series tachometer  tachometer 11-pin socket 1-stage (1 input and output) 6 digits contact output (spdt) 100 to 240 vac h7cx-r11-n 12 to 24 vdc/24 vac h7cx-r11d1-n 1-stage (2 inputs and outputs) contact output (spdt + spst) 100 to 240 vac h7cx-r11w-n 12 to 24 vdc/24 vac h7cx-r11wd1-n 4. settings * the h7cx-r11w @ is a 1-stage (2 inputs and outputs) rather than a 2-stage counter. 5. output type 6. supply voltage symbol meaning none 1-stage setting u factory-set to 1-stage setting w factory-set to 2-stage setting* symbol meaning none contact output or contact output + transistor output s transistor output symbol meaning none 100 to 240 vac at 50/60 hz d 12 to 24 vdc d1 12 to 24 vdc/24 vac at 50/60 hz 1. type 2. external connections 3. digits symbol meaning a standard type r tachometer symbol meaning none screw terminals 11 11-pin socket symbol meaning none 6 digits 4 4 digits
4 h7cx- @ -n accessories (order separately) front panels (replacement part) note: 1. you can change the color of the front panel when mounting the c ounter. the counter is shipped with a black (n1.5) front panel. 2. "counter" is printed on the front of replacement front panels. soft cover hard cover flush mounting adapter waterproof packing connection sockets terminal covers for p3ga -11 back-connecting socket model color applicable counters page y92p-cxc4g light gray (5y7/1) 4-digit counter 12 y92p-cxc4s white (5y9.2/0.5) y92p-cxc4b black (n1.5) y92p-cxc6g light gray (5y7/1) 6-digit counter y92p-cxc6s white (5y9.2/0.5) y92p-cxc6b black (n1.5) model remarks page y92a-48f1 --- 12 model remarks page y92a-48 --- 12 model remarks page y92f-30 included with models with screw terminals. 12 y92f-45 use this adapter to install the counter/ tachometer in a cutout previously made for a din 72 72 mm device (panel cutout: 68 68 mm). model remarks page y92s-29 included with models with screw terminals. 12 model classification connectable counter/ tachometers remarks page p2cf-11 front-connecting socket h7cx- @ 11 @ -n --- 13 p2cf-11-e front-connecting socket (finger-safe type) round crimp terminals cannot be used on finger-safe sockets. use forked crimp terminals. p3ga-11 back-connecting sockets a y92a-48g terminal cover can be used with the socket to create a finger-safe construction. model remarks page y92a-48g --- 13
h7cx-a@ -n 5  easy to check the output status from a long distance with changing display colors *1 (red, green, and orange).  includes total and preset counter, batch counter, dual counter, twin counter, and tachometer. *2 *1. not supported by the h7cx-a11 @ -n. *2. the functions that can be selected depend on the model. specifications ratings *1. 1-stage preset counter and total counter functionality. *2. do not use the output from an inverter as the power supply.the ripple must be 20% maximum for dc power. *3. a response of 10 khz is possible if the response speed is 5 khz and the 1-stage preset counter input mode is increment, decr ement, or increment/ decrement (command input). *4. the display is lit only when the power is on. nothing is displayed when power is off. h7cx-a @ -n multifunction preset counter item models h7cx-a114 @ -n h7cx-a11 @ -n h7cx-a4 @ -n h7cx-a @ -n h7cx-a4w @ -n h7cx-aw @ -n/-au @ -n classification preset counter preset counter/ tachometer configuration 1-stage preset counter, 1-stage preset counter with total counter (selectable)*1 1-stage/2-stage preset counter, total and preset counter*1, batch counter, dual counter, and twin counter (selectable) 1-stage/2-stage preset counter, total and preset counter*1, batch counter, dual counter, twin counter, and tachometer (selectable) ratings power supply voltage*2  100 to 240 vac, 50/60 hz  24 vac, 50/60 hz or 12 to 24 vdc  100 to 240 vac, 50/60 hz 12 to 24 vdc  100 to 240 vac at 50/ 60 hz  24 vac at 50/60 hz or 12 to 24 vdc  12 to 24 vdc operating volt- age fluctuation range 85% to 110% of rated supply voltage (12 to 24 vdc: 90% to 110%) power con- sumption approx. 9.4 va at 100 to 240 vac, approx. 7.2 va/4.7 w at 24 vac/12 to 24 vdc, approx. 3.7 w at 12 to 24 vdc mounting method flush mounting or surface mounting flush mounting external connections 11-pin socket screw terminals degree of protection iec ip66, ul508 type 4x (indoors) for panel surface only and only when y92s-29 waterproof packing is used. input signals cp1, cp2, reset, and total reset cp1, cp2, reset 1, and reset 2 counter maximum counting speed 30 hz or 5 khz (switchable) (on/off ratio 1:1)*3 *common setting for cp1 and cp2 input mode increment, decrement, increment/decrement (up/down a (command input), up/down b (individual inputs), or up/down c (quadrature i nputs)) output mode n, f, c, r, k-1, p, q, a, k-2, d, and l. n, f, c, r, k-1, p, q, a, k-2, d, l, and h. one-shot out- put time 0.01 to 99.99 s reset system external (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to c, r, p, a nd q mode operation) tachometer refer to the separate table for tachometer function ratings. prescaling function yes (0.001 to 9.999) yes (0.001 to 99.999) yes (0.001 to 9.999) yes (0.001 to 99.999) yes (0.001 to 9.999) yes (0.001 to 99.999) decimal point adjustment yes (rightmost 3 digits) sensor waiting time 290 ms max. (control output is turned off and no input is accepted during sensor waiting time.) input method no-voltage inputs: on impedance: 1 k ? max. (leakage current: 12 ma at 0 ? ) on residual voltage: 3 v max. off impedance: 100 k ? min. voltage input: high (logic) level: 4.5 to 30 vdc low (logic) level: 0 to 2 vdc (input resistance: approx. 4.7 k ? ) no-voltage input/voltage input (switchable) external power supply 12 vdc ( 10%), 100 ma (except for h7cx-a @ d models) refer to precautions for correct use on page page 53 for details. control output  contact output: 3 a at 250 vac/30 vdc, resistive load (cos =1), minimum applied load: 10 ma at 5 vdc (failure level: p, reference value)  transistor output: npn open collector, 100 ma at 30 vdc, residual voltage: 1.5 vdc max. (approx. 1 v), leakage current: 0.1 ma max. display*4 7-segment, negative transmissive lcd character height count value: 12 mm (red) set value: 6 mm (green) 7-segment, negative transmissive lcd character height count value: 10 mm (red) set value: 6 mm (green) 7-segment, negative transmissive lcd character height count value: 12 mm (red, green, or orange selectable) set value: 6 mm (green) 7-segment, negative transmissive lcd character height count value: 10 mm (red, green, or orange selectable) set value: 6 mm (green) 7-segment, negative transmissive lcd character height count value: 12 mm (red, green, or orange selectable) set value: 6 mm (green) 7-segment, negative transmissive lcd character height count value: 10 mm (red, green, or orange selectable) set value: 6 mm (green) digits 4 digits ? 999 to 9999 ( ? 3 digits to +4 digits) 6 digits ? 99999 to 999999 ( ? 5 digits to +6 digits) 4 digits ? 999 to 9999 ( ? 3 digits to +4 digits) 6 digits ? 99999 to 999999 ( ? 5 digits to +6 digits) 4 digits ? 999 to 9999 ( ? 3 digits to +4 digits) 6 digits ? 99999 to 999999 ( ? 5 digits to +6 digits), tachometer: 0 to 999999 memory backup eeprom (overwrites: 100,000 times min.) that can store data for 10 years min. operating temperature range ? 10 to 55 c ( ? 10 to 50 c if counter/tachometers are mounted side by side) (with no icing or condensation) storage temperature range ? 25 to 70 c (with no icing or condensation) operating humidity range 25% to 85% case color black (n1.5) (optional front panels are available to change the front panel color to light gray or white.) attachments --- flush mounting adapter, waterproof packing, terminal cover flush mounting adapter, waterproof packing, terminal cover, label for dip switch settings
6 h7cx-a @ -n tachometer function ratings * an input off time of at least 20 ms is required. characteristics model item h7cx-a114 @ -n h7cx-a11 @ -n h7cx-a4 @ -n h7cx-a @ -n h7cx-a4w @ -n h7cx-aw @ -n/-au @ -n input mode no tachometer functionality selectable from independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs. pulse measurement method periodic measurement pulse width measurement maximum counting speed 30 hz 1-input mode: 10 khz other modes: 5 khz 30 hz 1-input mode: 10 khz other modes: 5 khz minimum input signal width --- --- 30 ms *1 1-input mode: 0.2 ms other modes: 0.4 ms* measuring ranges 0.01 to 30.00 hz 1-input mode: 0.01 to 10 khz, other modes: 0.01 to 5 khz 0.030 to 999999 s 1-input mode: 0.0002 to 99999 s other modes: 0.0004 to 99999 s sampling period 200 ms min. 200 ms min. or continuous selectable (minimum interval of 10 ms) continuous (minimum interval of 10 ms) measuring accuracy 0.1% fs 1 digit max. (at 23 5 c) output mode input mode: not 2-input independent measurement: hi-lo, area, hi-hi, lo-lo 2-input independent measurement: hi-hi, lo-lo auto-zero time 0.1 to 999.9s startup time 0.0 to 99.9s averaging simple averaging/moving averaging selectable, processing: off, 2, 4, 8, or 16 times hold input minimum input signal width: 20 ms * refer to the life-test curve. applicable standards * the following safety standards apply to models with sockets (h7cx-a11 @ or h7cx-a114 @ ). cul (listing): applicable when an omron p2cf(-e) socket is used. cur (recognition): applicable when any other socket is used. insulation resistance 100 m ? min. (at 500 vdc) between current-carrying terminals and exposed non- current-carrying metal parts, and between non-continuous contacts dielectric strength 2,000 vac, 50/60 hz for 1 min between current-carrying metal parts and non- current-carrying metal parts 2,000 vac, 50/60 hz for 1 min between power supply and input circuit for all models except h7cx- @ d @ (1,000 vac for 24 vac/12 to 24 vdc) 1,000 vac (for h7cx- @ sd @ ), 50/60 hz for 1 min between control output, power supply, and input circuit (2,000 vac for models other than h7cx- @ sd @ ) 1,000 vac, 50/60 hz for 1 min between non-continuous contacts impulse withstand voltage 3.0 kv between power terminals (1.0 kv for models with 24 vac/12 to 24 vdc or 12 to 24 vdc) 4.5 kv between current-carrying terminals and exposed non-current-carrying metal parts (1.5 kv for models with 24 vac/12 to 24 vdc or 12 to 24 vdc) noise immunity 1.5 kv between power terminals ( 480 v for models with 12 to 24 vdc) 600 v between input terminals square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) static immunity malfunction: 8 kv destruction: 15 kv vibration resistance destruction 10 to 55 hz with 0.75-mm single amplitude each in three directions for 2 h each malfunction 10 to 55 hz with 0.35-mm single amplitude each in three directions for 10 min each shock re- sistance destruction 300 m/s 2 each in three directions malfunction 100 m/s 2 each in three directions life expectancy mechanical: 10,000,000 operations min. electrical: 100,000 operations min. (3 a at 250 vac, resistive load, ambient temperature condition: 23 c)* weight approx. 130 g (counter only) approved safety standards culus (or curus): ul508/csa c22.2 no. 14* en 61010-1 (iec 61010-1): pollution degree 2/overvoltage category ii b300 pilot duty 1/4 hp 120 vac, 1/3 hp, 240 vac, 3 a resistive load vde0106/p100 (finger protection) emc (emi) en61326 emission enclosure: en 55011 group 1 class a emission ac mains: en 55011 group 1 class a (ems) en61326 immunity esd: en 61000-4-2: 4 kv contact discharge; 8 kv air discharge immunity rf-interference: en 61000-4-3: 10 v/m (amplitude-modulated, 80 mhz to 1 ghz); 10 v/m (pulse-modulated, 900 mhz 5 mhz) immunity conducted disturbance: en 61000-4-6: 10 v (0.15 to 80 mhz) immunity burst: en 61000-4-4: 2 kv power-line; 1 kv i/o signal-line immunity surge: en 61000-4-5: 1 kv line to lines (power and output lines); 2 kv line to ground (power and output lines) immunity voltage dip/interruption: en 61000-4-11: 0.5 cycle, 100% (rated voltage) l if e-test c urve ( re f erence values) resistive load inductive load a current of 0.15 a max. can be switched at 125 vdc (cos =1) and current of 0.1 a max. can be switched if l/r=7 ms. in both cases, a life of 100,000 operations can be expected. 1,000 700 500 300 100 70 50 load current ( a ) 01 2 34 30 vdc (cos =1) 250 vac (cos =1) no. of operations ( 10 3 ) 1,000 700 500 300 100 70 50 01 2 34 30 vdc (l/r=7 ms) load current (a) 250 vac (cos =1) no. of operations ( 10 3 )
h7cx-a @ -n 7 i/o functions using as a counter *1 *1. for information on operation of i/o functions, refer to pages page 22 to page 25. *2. in increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with 2-stage models. *3. reset operates as described in the following table. (the reset indicator will not be lit.)  the following table shows the delay from when the reset signal is input until the out put is turned off. (reference values) operating procedures (tachometer function) inputs cp1, cp2 (1) in general (except for dual counter mode)  reads counting signals.  increment, decrement, command, individual, and quadrature inputs accepted. (2) when used as a dual counter or twin counter  reads cp1 count signals with cp1 input and cp2 count signals with cp2 input.  increment signals can be input. reset/reset 1 (1) in general (except for dual counter mode)  resets present value and outputs (out2 when using the batch counter)*2.  counting cannot be performed during reset/reset 1 input.  reset indicator is lit while reset input is on. (2) when used as a dual counter or twin counter.  resets the cp1 present value (to 0).  counting for cp1 input cannot be performed while the reset 1 input is on.  the reset indicator is lit while the reset 1 input is on. total reset or reset 2 the reset function depends on the selected configuration*3. outputs out1, out2 outputs signals according to the specifie d output mode when a set value is reached. configuration reset operation 1-stage/2-stage preset counter does not operate (not used). total and preset counter  resets the total count value.  the total count value is held at 0 while the total reset input is on. batch counter  resets the batch count va lue and batch output (out1).  the batch count value is held at 0 while the reset 2 input is on. dual counter  resets the cp2 present value.  counting for cp2 input cannot be performed while the reset 2 input is on. twin counter  resets the cp2 present value. minimum reset signal width output delay time 1 ms 0.8 to 1.2 ms 20 ms 15 to 25 ms inputs cp1, cp2 reads counting signals. (the cp2 in put can be used when the input mode is not 1-input mode.) reset/reset 1  holds the measurement value and outputs. (the reset 2 input can be used when the input mode is 2-input independent measurement.)  the reset indicator is lit when the value is being held. outputs out1, out2 outputs signals according to the specified output mode when a set value is reached.
h7cx-a @ -n 8 connections terminal arrangement confirm that the power supply meets specifications before use. transistor output  the transistor output of the h7cx is isolated from the internal circuitry by a photocoupl er, so the transistor output can be used as both npn and pnp output.  the diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the h7cx. h7cx-a-n/-a4-n h7cx-ad-n/-a4d-n h7cx-as-n/-a4s-n 1-stage contact output 1-stage contact output terminals 1 and 6 are connected internally. 1-stage transistor output h7cx-asd-n/-a4sd-n H7CX-AW-N/-a4w-n/-awd1-n/-au-n/-aud1-n h7cx-aws-n/-awsd1-n/-ausd1-n 1-stage transistor output terminals 1 and 6 are connected internally. 2-stage contact output 2-stage transistor output h7cx-awsd-n/-a4wsd-n h7cx-a11-n/-a114-n/-a11d1-n/-a114d1-n h7cx-a11s-n/-a114s-n/-a11sd1-n 2-stage transistor output terminals 1 and 6 are connected internally. 1-stage contact output 1-stage transistor output 678910 11 out ( ? ) ( + ) 0 v 12345 reset total reset cp2 cp1 sensor 12 vdc external power supply 678910 out ( + ) ( ? ) 0 v 12345 reset total reset cp2 cp1 678910 11 12345 out 0 v ( ? ) ( + ) reset total reset cp2 cp1 sensor 12 vdc external power supply 678910 0 v 12345 out ( + ) ( ? ) reset cp2 cp1 total reset 678910 11 12 13 out1 12345 out2 ( + ) ( ? ) 0 v ( ? ) ( + ) reset 1 cp2 cp1 12 vdc external power supply reset 2 sensor 12 13 * 1 1: ?-au @ ? models * * 678910 11 12 13 12345 out1 out2 0 v ( + ) ( ? ) ( ? ) ( + ) reset 1 cp2 cp1 sensor 12 vdc external power supply reset 2 678910 12 13 0 v 12345 out1 out2 ( + ) ( ? ) reset 1 cp2 cp1 reset 2 6 7 8 9 10 11 1 2 3 4 5 ( + ) ( ? ) out 0 v ( ? ) ( + ) reset total reset cp2 cp1 sensor 12 vdc external power supply internal circui t 6 7 8 9 10 11 1 2 3 4 5 0 v out ( + ) ( ? ) ( ? ) ( + ) reset total reset cp2 cp1 sensor 12 vdc external power supply internal circui t power for load + load power for load + load npn output pnp output power for load + counter inductive load
h7cx-a @ -n 9 block diagram note: all models except for h7cx- @ d-n have basic insulation. input circuits cp1, cp2, reset/reset 1, and total reset/reset 2 input input connections the inputs of the h7cx- @ -n are no-voltage (short-circuit or open) inputs or voltage inputs. no-voltage inputs (npn inputs) no-voltage input signal levels note: the dc voltage must be 30 vdc max. voltage inputs (pnp inputs) voltage input signal levels note: 1. the dc voltage must be 30 vdc max. 2. input resistance: approx. 4.7 k ? output circuit (see note.) display circuit input circuits (basic insulation) (basic insulation) internal control circuit power supply circuit key switch circuit no-voltage inputs (npn inputs) voltage inputs (pnp inputs) internal circuit in +14v 1 k ? in approx. 4.7 k ? internal circuit open collector voltage output contact input dc two-wire sensor h7cx-a @ h7cx-a11 @ note: operates with transistor on. plc or sensor 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input h7cx-a @ h7cx-a11 @ note: operates with transistor on. sensor 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input note: operates with relay on. h7cx-a @ h7cx-a11 @ 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input note: operates with transistor on. h7cx-a @ h7cx-a11 @ 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input no-contact input short-circuit level (transistor on)  residual voltage: 3 v max.  impedance when on: 1 k ? max. (the leakage current is approx. 12 ma when the impedance is 0 ? .) open level (transistor off)  impedance when off: 100 k ? min. contact input use contacts which can adequately switch 5 ma at 10 v. applicable two-wire sensor  leakage current: 1.5 ma max.  switching capacity: 5 ma min.  residual voltage: 3 vdc max.  operating voltage: 10 vdc no-contact input (npn transistor) no-cont act input (pnp transistor) contact input note: operates with transistor off. h7cx-a @ h7cx-a11 @ sensor 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input note: operates with transistor on. h7cx-a @ h7cx-a11 @ sensor 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input note: operates with relay on. h7cx-a @ h7cx-a11 @ 678910 37564 0 v for inputs reset/reset 1 input cp2 input cp1 input total reset/reset 2 input high level (input on): 4.5 to 30 vdc low level (input off): 0 to 2 vdc
10 h7cx-a @ -n nomenclature dimensions (unit: mm) counters on (enable) (default setting) off (disable) rst 11 10 9 10 11 8 6 7 4 12 13 8 6 7 12 5 4 1st digit 4th digit 1st digit 6th digit 1 1 2 2 3 3 5 1 4 1 1 2 4 display section 3. reset indicator (orange) 1. key protect indicator (orange) 2. control output indicator (orange) 4. total count indicator 6. set value 1, 2 stage indicator 8. set value (sub-display) (character height: 6 mm, green) 9. hold display (orange) out: (one-stage) out: (two-stage) (lit when the total count value is displayed.) (lit when the reset input (1) or reset key is on.) displayed only when the configuration selection mode is not tachometer mode. 5. batch indicator (lit when the batch count value is displayed.) operation keys 10. mode key (changes modes and setting items.) 11. reset key (see note.) 12. up keys to 1 6 (6-digit models: to ) 13. down keys to switches 14. key-protect switch 15. dip switch 7. present value (main display) (character height: 12 mm (6-digit: 10 mm), red*) (front view of 4-digit model) (front view of 6-digit model) * characters on models with screw terminals (h7cx-a11 @ ) can be switched between red, green, and orange. displayed only when the configuration selection mode is not tachometer mode. off on 12345678 note: the reset functions depends on the selected configuration. configuration reset operation 1-stage/2-stage preset counter resets the present value and outputs. total and preset counter  resets the present value and outputs.  when the total count value is displayed, resets the present value, the total count value, and outputs. batch counter  resets the present value and out2.  when the batch count value is displayed, resets the present value, the batch count value, and outputs. dual counter resets the cp1 present value, cp2 present value, dual count value, and outputs. twin counter resets the cp1 present value and output 1 when the cp1 present value is displayed. resets the cp2 present value and output 2 when the cp2 present value is displayed. tachometer holds the measurement value and outputs (hold function). (when the input mode is 2-input independent measurement, the cp1 measurement value display will hold the cp1 measurement value and output 1 and the cp2 measurement value display will hold the cp2 measurement value and output 2.) 14 1 5 model with 4 digits 6 mm 12 mm character size for sub-display character size for main display model with 6 digits 10 mm 6 mm character size for sub-display character size for main display 44.8 44.8 78 48 48 6 h7cx-a-n/-as-n/-aw-n/-aws-n/-a wd1-n/-awsd1-n/-a4-n/-a4s-n/-a4w-n/-au-n/-aud1-n/-ausd1-n (flush mounti ng models) note: m3.5 terminal screw (effective length: 6 mm)
h7cx-a @ -n 11 dimensions with flush mounting adapter 48 48 44.8 44.8 59 6 h7cx-ad-n/-asd-n/-awsd-n/-a4d-n/-a4sd- n/-a4wsd-n (f lush mounting models) note: m3.5 terminal screw (effective length: 6 mm) 48 48 44.8 44.8 63.7 14.4 6 h7cx-a11-n/-a11s-n/-a11d1-n/-a11sd1-n /-a114-n/-a114s-n/-a114d1-n (flush mounting/surface mo unting models) 58 48 76.5 7.5 panel y92f-30 (provided) flush mounting adapter y92s-29 (provided) waterproof packing (51) h7cx-a-n/-as-n/-aw-n/- aws-n/-awd1-n/-awsd1-n/-a4-n/-a4s-n/-a4w-n (provided with adapter and waterproof packing) panel cutouts panel cutouts are as shown below. (according to din43700). note: 1. the mounting panel thickness should be 1 to 5 mm. 2. to allow easier operation, it is recommended that adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm). 3. it is possible to mount counters side by side, but only in the direction without the hooks. if they are mounted side-by-side, water- resistance will be lost. dimensions with front connecting socket * these dimensions depend on the kind of din track. (reference value) 60 min. 60 min. 15 min. 45 + 0.6 0 45 + 0.6 0 a with y92a-48f1 attached. with y92a-48 attached. a=(48n ? 2.5) +1 ? 0 a=(51n ? 5.5) +1 ? 0 a={48n ? 2.5+(n ? 1) 4} +1 ? 0 n units mounted side by side 103.2* 100.9 h7cx -a11 @ p2cf-11(-e) front connecting socket (order separately) 58 48 (51) 7.5 57.5 panel y92f-30 (provided) flush mounting adapter y92s-29 (provided) waterproof packing h7cx-ad-n/-asd-n/-awsd-n /-a4d-n/-a4sd-n/-a4wsd-n (provided with adapter and waterproof packing) 58 48 (51) 7.5 89.9 panel y92f-30 (order separately) flush mounting adapter y92s-29 (order separately) waterproof packing h7cx-a11-n/-a11s-n/-a11d1-n/-a11sd1-n/-a114-n/-a114s-n/-a114d1-n (adapter and waterproof pa cking ordered separately)
12 h7cx-a @ -n accessories (order separately) front panel (replacement part) you can change the color of the front panel when mounting the counter/tachometer. the counter/t achometer is shipped with a black (n1.5) front panel. "counter" is printed on the front of replacement front panels. protecting the counter/tachometer in environments subject to oil the waterproof packing will dete riorate, harden, and shrink depending on the application environment. to ensure maintaining the ip @ 6, ul type 4x waterproof level, periodically replace the waterproof packing. the periodic replacement period will depend on the application environment. y ou must confirm the proper replacement period. use 1 year or less as a guideline. if the waterproof packing is not replaced periodically, the waterproof level will not be maintained. it is not necessary to mount the waterproof packing if waterproof construction is not required. note: depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. therefore, it is recommended that resin products are replaced regularly. y92p- c x c 4 g 4-digit counter light gray (5y7/1) y92p-cxc4s 4-digit counter white (5y9.2/0.5) y92p-cxt4b 4-digit counter black (n1.5) replacement method the front panel is attached to the counter/tachometer with tabs in four locations. to remove the front panel, open the tabs and pull the front panel forward. to attach the front panel, press it onto the counter/tachometer so that all four tabs lodge into the grooves on the body of the counter/tachometer. ta b s grooves y92p-cxt6g 6-digit counter light gray (5y7/1) y92p-cxt6s 6-digit counter white (5y9.2/0.5) y92p-cxt6b 6-digit counter black (n1.5) the h7cx's panel surface is wa ter-resistive (conforming to ip @ 6, ul type 4x) and so even if drops of water penetrate the gaps between the keys, there will be no adv erse effect on internal circuits. if, however, there is a possibili ty of oil being present on the operator's hands, use the soft co ver. the soft cover ensures protection equivalent to ip54f agai nst oil. do not, however, use the h7cx in locations where it would come in direct contact with oil. soft cover y92a-48f1 hard cover y92a-48 y92f-45 use this adapter to install the counter/ tachometer in a cutout previously made for a din 72 72 mm device (panel cutout: 68 68 mm). flush mounting adapter y92f-30 order the flush mounting adapter with the following model number separately if it is lost or damaged. note: the waterproof packing is included with models with screw terminals. waterproo f pack i ng y92s-29 note: the waterproof packing is included with models with screw terminals. order the waterproof packing separately if it is lost or damaged. the waterproof packing can be used to achieve ip66 protection.
h7cx-a @ -n 13 connection sockets front connecting socket note: round crimp terminals cannot be used on finger -safe sockets. use forked crimp terminals. back-connecting sockets note: a y92a-48g terminal cover can be used with t he socket to create a finger-safe construction. terminal covers for p3ga-11 back-connecting socket note: the terminal cover can be used with a back-mounting socket (p3ga-11) to create a finger-safe construction. model dimensions terminal arrangement and internal connections mounting hole dimensions p2cf-11 (top view) note: the socket can also be mounted to din track. p2cf-11-e (finger-safe type) model dimensions terminal arrangement and internal connections p3ga-11 (bottom view) model dimensions y92a-48g 4 70 max. 50 max. two, 4.5-dia. holes eleven, m3.5 7.5 sems screws 7.8 31.2 max. 4 3 8 7 6 5 10 11 1 2 9 3 4 40 0.2 two, m4 or 4.5-dia. holes 10 11 12 7 865 3 4 9 p2cf-11-e 10a250vac resistive 4 40 0.2 7.8 30 4.5 35. 4 1.2 3 5 70 max. 50 max. two, 4.5-dia. holes eleven, m3.5 7.5 set screws 31.2 max. 27 dia. 4.5 16.3 6.2 25.6 45 45 8 7 6 4 3 9 5 10 11 1 2 y92a-48g up p c 34 twelve, 6.4-dia. holes 47.7 47.7 48 48 27.6 24.6 16.5 47.4
14 h7cx-a @ -n optional products for track mounting note: order spacers in increments of 10. 1 35 0.3 7.3 0.15 27 0.15 4.5 15 25 25 10 15 (5)* 10 25 25 1,000 (500)* * the values shown in parentheses are for the pfp-50n. mounting track pfp-100n pfp-50n 15 25 25 1,000 4.5 25 25 15 10 1 24 27 35 0.3 16 1.5 29.2 10 mounting track pfp-100n2 4.8 1.3 35.5 35.3 1.8 1 1.8 10 6.2 m4 spring washer 50 11.5 10 m4 8 pan head screw end plate pfp-m 5 16 12 44.3 34.8 16.5 spacer pfp-s
h7cx-a @ -n 15 counter operating procedures setting procedure guide setting for counter operation * use the following settings. setting for tachometer operation * refer to page page 27. * at the time of delivery, the h7cx is set to the 1-stage preset counter configuration. (2-stage models are set to the 2-stage p reset counter configuration.) refer to page page 35 for information on switching models. i/o functions for counter operation after making dip switch settings for basic operations , advanced functions can be added using the operation keys. for details, refer to page page 16. key-protect switch disabled enabled off on off on off off on on n f c k-1 up down refer to the table on the right. 30 hz 5 khz 20 ms 1 ms dip switch settings counting speed input mode output mode minimum reset signal input selection output time 0.5 s 0.05 s npn pnp note: all pins are factory-set to off. ? when setting functions using the dip switch, be sure to set pin 1 of the dip switch to on. ? dip switch settings are effective when the power is turned on again. (perform dip switch settings while the power is off.) step1 step3 set the basic parameters. (if the desired i/o mode is not listed below or to set all parameters using the front panel keys, perform , below.) note: can be performed first, followed by . note: the configuration that can be selected depends on the model. * the default mode is 1-stage preset counter configuration (2-stage preset counter configuration for 2-stage models). item off on output mode pin 5 pin 4 1 2 3 4 5 6 7 8 step2 step2 step1 hold down for 1 s min. select the function from table 1 using the u ( d ) key. run mode power on 1 + hold down for 1 s min. 1 + twn the h7cx-a @ -n is a counter that contains more than one functional counter. when using the counter in any mode other than the default mode*, use the following chart to enter configuration selection mode and set the functions that are suitable to the application. (1-stage preset counter) (2-stage preset counter) (total and preset counter) (batch counter) (dual counter) (twin counter) (tachometer) configuration selection mode be sure to set pin 1 to on. off on 12345678
16 h7cx-a @ -n counter run mode power on function setting mode *3 *7 *5 displayed for output modes other than k-2, d, l, and h only. *5 *5 *6 displayed only when the input mode is ud-a , ud-b , or ud-c . (not displayed when the function is set to twn .) note: displayed only when the output mode is c, r, k-1, p, q, a, or k-2. note: displayed for terminal-block models (except h7cx-a11 @ ) only. *3 when using dual counter operation *7 set each digit using the individual u ( d ) keys. note: displayed only when the output mode is c, r, k-1, p, q, a, or k-2. note: displayed for output modes other than d, l, and h. hold cannot be set when the output mode is k-2. *7 set each digit using the individual u ( d ) keys. note: displayed only when twin counter mode is not selected. (red) (green) (orange) (red-green) (green-red) (red-orange) (orange-red) (green-orange) (orange-green) 3 s min. *2 3 s min. *1 step3 parameters that cannot be set with the dip switch are set with the operation keys on the front panel. change to function setting mode. input mode (cntm) output time (otim) output mode (outm) npn/pnp input mode (imod) display color (colr) (1 ms) (20 ms) (no decimal point) prescale value (pscl) counting speed (cnts) (30 hz) (5 khz) (pnp input) (npn input) the characters displayed in reverse video are the default settings. when performing settings with operation keys only, set pin1 of the dip switch to off (factory setting). if pin 1 of the dip switch is set to on, the setting items indicated by will not be displayed. for 6-digit models, only u keys are provided. displays for 6-digit models are given in parentheses. (n) (0.50 s) (99.99 s) (0.01 s) (0.01 s) (99.99 s) (outputs held) (f) (c) (r) (k-1) (p) (q) (a) (k-2) (d) (l) (h) *6 *6 *6 *6 (down) ( up/down a )( up/down b )( up/down c ) (up) (99.999) (1.000) (0.001) (0.50 s) (99.99 s) (0.01 s) to next page from next page (addition) (subtraction) *4 reset input signal width (iflt) decimal point position (dp)  set the input mode using the u ( d ) keys.  set the output mode using the u ( d ) keys.  set each digit using the individual u ( d ) keys.  set the counting speed using the u ( d ) keys.  set the reset input signal width using the u ( d ) keys.  set the decimal point position using the u ( d ) keys. (one digit after decimal point) (two digits after decimal point) (three digits after decimal point)  set each digit using the individual u ( d ) keys. (9.999)  set the npn/pnp input mode using the u ( d ) keys.  set the display color using the u ( d ) keys. dual count calculating mode (add)  set the dual count calculating mode using the ud keys. *4 displayed only when the output mode is k-2, d, l, or h. when using as a 2-stage preset counter one-shot output 2 time (otm2) one-shot output 1 time (otm1) note: displayed only when the output mode is c, r, k-1, p, q, a, or k-2. (0.50 s) (99.99 s) (0.01 s) when using as a batch counter one-shot output 2 time (otm2) function setting mode grn red org r-g g-r r-o o-r g-o o-g up down n f 0.01 99.99 0.50 30hz 1ms 0.001 99.999 9.999 1.000 pnp npn 20ms cr k -1 k -2 pqa dlh sub add 0.50 hold 0.01 99.99 0.01 0.50 99.99 0.01 99.99 ud-a ud-b ud-c *1 if the mode is switched to the function setting mode during operation, operation will continue. *2 changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. also , when settings are changed, the counter is reset (present value initialized and output turned off) on returning to run mode. if the output time is 0.00, hold is displayed. note: displayed only when the output mode is c, r, k-1, p, q, or a. note: displayed only when the output mode is c, r, k-1, p, q, or a. (0.50 s) (99.99 s) (0.01 s) twin counter output 2 output time (otm2) output 1 output time (otm1) 0.50 0.01 99.99 (0.50 s) (99.99 s) (0.01 s) 0.50 0.01 99.99 for details on operations and display in run mode, refer to page page 20. the display depends on the selected configuration.
h7cx-a @ -n 17 counter (9999 1000 times) (0 1000 times) (ofst) (abs) (kp-1) (kp-2) (kp-3) (kp-4) (kp-5) (kp-6) (kp-7) (9999 1000 times) (0 1000 times) (9999 1000 times) (0 1000 times) 9999 0 9999 0 9999 0 ( 9999 ) ( 1 ) 9999 1 ( 9999 ) ( 1 ) 9999 1 ( 9999 ) ( 1 ) 9999 1 ofst abs kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 (on) (off) on off *8 note: 1 to 999999 for 6-digit models *8 set each digit using the individual u ( d ) keys. note: the monitor value is only displayed. it cannot be set. forecast setting upper limit (pl-h) key protect level (kypt) from previous page to previous page output on count alarm set value/monitor value  make the absolute value setting and forecast setting using the u ( d ) keys.  set each digit using the individual u ( d ) keys.  set each digit using the individual u ( d ) keys.  set the key protect level using the u ( d ) keys. procedure for models other than ?- @ w @ ? models output on count alarm set value output on count monitor value output 1 (out1) on count alarm set value function setting mode absolute value setting/forecast value setting (setm) set value upper limit (sl-h) note: 1 to 999999 for 6-digit models. note: 1 to 999999 for 6-digit models. note: displayed only when the output mode is set to bcnt .  set each digit using the individual u ( d ) keys. procedure for ?- @ w @ ? models note: the monitor value is only displayed. it cannot be set. note: the monitor value is only displayed. it cannot be set. output 2 (out2) on count alarm set value output 1 (out1) on count monitor value output 2 (out2) on count monitor value batch count upper limit (bl-h) note: displayed only when the configuration selection mode is set to the 2-stage function 2cnt . note: displayed only when the configuration selection mode is set to the 2-stage function 2cnt and a forecast value is set. output allocation change note: displayed only for "-au @ " models. off : output 1 = 12, 13, output 2 = 3, 4, 5 on : output 1 = 3, 4, 5, output 2 = 12, 13 the numbers are the terminals numbers.
18 h7cx-a @ -n counter explanation of functions items marked with stars can be set using the dip switch. input mode ( cntm ) set increment mode (up), decrement mode (down), or one of the increment/decrement modes (up/down a, up/down b, or up/ down c) as the input mode. input modes other than up or do wn modes cannot be set using the dip switch and so use the operation keys if other modes are required. (for details on the operation of the input modes, refer to input modes and present value on page page 21.) dual count calculating mode ( calm ) when using as a dual counter, sele ct either add (addition) or sub (subtraction) as the calculati on method for the dual count value. add: dual count value = cp1 pv + cp2 pv sub: dual count value = cp1 pv ? cp2 pv output mode ( outm ) set the way that control output for the present value is output. the possible settings are n, f, c, r, k-1, p, q, a, k-2, d, l, and h. output modes other than n, f, c, or k-1 cannot be set using the dip switch and so use the operation keys if other modes are required. the output modes that can be set vary with the model. (for details on the operation of the output modes, refer to input/ output mode settings on page page 22.) one-shot output time ( otim ) set the one-shot output time (0.01 to 99.99 s) for control output. one-shot output can be used only when c, r, k-1, p, q, a, or k-2 is selected as the output mode. output times other than 0.5 s or 0.05 s cannot be set with the dip switch and so use the operation keys if other settings are required. one-shot output 2 time ( otm2 ) set the one-shot output time (0.01 to 99.99 s) for control output (out2). one-shot output can be used only when c, r, k-1, p, q, a, or k-2 is selected as the output mode. output times other than 0.5 s or 0.05 s cannot be set with the dip switch and so use the operation keys if other settings are required. one-shot output 1 time ( otm1 ) set the one-shot output time (0.01 to 99.99 s) for control output (out1). one-shot output can be used only when d, l, or h is selected as the output mode. if the output time is set to 0.00, hold is displayed, and outputs are held. counting speed ( cnts ) set the maximum counting speed (30 hz/5 khz) for cp1 and cp2 inputs together. if contacts are used for input signal s, set the counting speed to 30 hz. processing to eliminate chatteri ng is performed for this setting. reset input signal width ( iflt ) set the reset input signal width (20 ms/1 ms) for reset/reset 1 and total reset/reset 2 inputs together. if contacts are used for the input si gnal, set the input signal width to 20 ms. processing to eliminate cha ttering is performed for this setting. decimal point position ( dp ) decide the decimal point position for the present value, cp1/cp2 present values, set value (sv1, sv2), total count value, and dual count set value. prescale value ( pscl ) pulses input to the counter are c onverted according to the specified prescale value. (setting range: 0.001 to 99.999 for 6-digit models and 0.001 to 9.999 for 4-digit models.) example: to display the feed distance for systems that output 25 pulses for a feed length of 0.5 m in the form @@ . @@ m: 1. set the decimal point pos ition to 2 decimal places. 2. set the prescale value to 0.02 (0.5 25).  observe the following points when setting a prescale value. set the set value to a value less than {maximum countable value ? prescale value}. example: if the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 ? 1.25). if the set value is set to a value great er than this, output will not turn on.  output will turn on, however, if a present value overflow occurs (ffffff or ffff). npn/pnp input mode ( imod ) select either npn input (no-voltage input) or pnp input (voltage input) as the input format. when usi ng a two-wire sensor, select npn input. the same setting is used for all external inputs. for details on input connections, refer to input connections on page page 9. display color ( colr ) (displayed for terminal block models (except h7cx-a11 @ ) only.) set the color used for the present value. * output 2 for 2-stage models. with the twin counter, output 1 and output 2 will both turn off when the output status is off. either output 1 or output 2 will turn on when the output status is on. output off* output on* red red (fixed) grn green (fixed) org orange (fixed) r-g red green g-r green red r-o red orange o-r orange red g-o green orange o-g orange green 25 pulses encoder 0.5 m note: if the prescale value setting is incorrect, a counting error will occur. check that the settings are correct before using this function.
h7cx-a @ -n 19 counter absolute value setting/forecast value setting ( setm ) for the 2 count output mode, an absolute value setting ( abs ) or forecast value setting ( ofst ) can be set for set value 1. when a forecast value is set, specify the forecast value set value (i.e., the deviation for the set value). the forecast output (output 1) turns on when the present value reaches the forecast value. if the forecast set value is greater than or equal to the set value, the forecast output (output 1) will turn on as soon as counting starts. if the forecast value setting is used, specify the set value 2 minus the forecast value setting for set value 1. set value upper limit ( sl-h ) set the upper limit for the set value when it is set in run mode. the setting can be made from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit models. forecast set upper limit ( pl-h ) set the upper limit for the forecast set value. the setting can be made from 1 to 9999 for 4-digit models and from 1 to 999999 for 6-digit models. batch count upper limit ( bl-h ) set the upper limit for the batch count value. the setting can be made from 1 to 9999 for 4-digit model s and from 1 to 999999 for 6-digit models. output allocation ( otst ) when using an h7cx-au @ -n model as a 2-stage counter, the output can be flexibly allocated to either stage 1 or 2. the transistor output can be allocated to sv1 and the contact output to sv2 or vice verse, as in the following tables. h7cx-au-n/-aud1-n h7cx-ausd1-n key protect level ( kypt ) set the key protect level. refer to key protect level on page page 36. output on count alarm set value ( on-a ) set the alarm value for the output on count. the limit can be set to between 0 1000 (0 times) and 9999 1000 (9,999,000 times). only the underlined values are set. the alarm will be disabled if 0 is set. if the total on count of the output exceeds the alarm set value, e3 will be displayed on the timer to i ndicate that the output on count alarm value was exceeded. refer to self-diagnostic function on page page 36 for information on the e3 display. on count alarm set values for outputs 1 and 2 (out1 and out2) ( on1a and on2a ) set the on count alarm values for the outputs 1 and 2. the limit can be set to between 0 1000 (0 times) and 9999 1000 (9,999,000 times). only the underlined values are set. the alarm will be disabled if 0 is set. if the total on count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the timer to indicate that the output on count alarm value was exceeded. refer to self-diagnostic function on page page 36 for information on the e3 display. output on count monitor value ( on-c ) the monitor value is only displayed. it cannot be set. the output on count will be 1,000 times the displayed value. on count monitor va lues for outputs 1 and 2 (out1 and out2) ( on1c and on2c ) the monitor value for output 1 or 2 is only displayed. it cannot be set. the output on count will be 1,000 times the displayed value. output 1 output 2 off transistor (12-13) contact (3, 4, 5) on contact (3, 4, 5) transistor (12-13) output 1 output 2 off transistor (12-13) transistor with diode (3, 4, 5) on transistor with diode (3, 4, 5) transistor (12-13) set value 2 set value 1 0 control output 1 (out1) control output 2 (out2) count value example: f mode set value forecast value forecast set value 0 forecast output (out1) control output (out 2) count value example: f mode
20 h7cx-a @ -n counter operation in run mode i/o functions for counter operation present value set value 1 present value set value present value set value 2 present value set value batch count value batch count set value present value 1 set value 1 present value 2 set value 2 present value set value total count value dual count value dual count set value cp1 present value cp2 present value present value set value present value forecast set value total and preset counter batch counter dual counter twin counter  set values for each digit as required using the u ( d ) keys. ( u key only for 6-digit models.) 1-stage preset counter 2-stage preset counter with absolute value setting  present value shows the present count value.  set values (set value 1 and set value 2) set the set values. when the present value reaches the set value (set value 1 or set value 2), a signal is output according to the specified output mode.  present value/set value same as 1-stage preset counter.  total count value shows the present total count value.  present value/set value same as 1-stage preset counter.  batch count value shows the number of times the count has been completed for the present value.  batch count set value set the batch count set value. when the batch count value reaches the batch count set value, batch output (out1) turns on.  dual count value shows the sum of the cp1 present value and cp2 present value when the dual count calculating mode is add and shows the value obtained by subtracting the cp2 present value from the cp1 present value when the dual count calculating mode is sub.  dual count set value set the dual count set value. when the dual count value reaches the dual count set value, signals are output according to the specified output mode.  cp1/cp2 present value show the present count values for cp1 and cp2 present values respectively.  present values 1 and 2 shows the present count value 1 or 2.  set values 1 and 2 setting for present value 1 or 2.  present value shows the present count value.  set values set the set values.  forecast set value set the deviation for the set value. 2-stage preset counter with forecast value setting
h7cx-a @ -n 21 counter input modes and present value (see note 1.) i/o functions for counter operation up (increment) mode down (decrement) mode cp1: count input; cp2: prohibit (gate) input must be greater than the minimum signal width. (see note 2.) cp1: count input; cp2: prohibit (gate) input must be greater than the minimum signal width. (see note 2.) cp1: prohibit (gate) input; cp2: count input must be greater than the minimum signal width. (see note 2.) cp1: prohibit (gate) input; cp2: count input must be greater than the minimum signal width. (see note 2.) * counting starts when the cp1 is turned on after turning on the power. up/down a command input mode up/down b individual input mode must be greater than the minimum signal width. (see note 2.) up/down c quadrature input mode note: 1. if the configuration selection is set to dual counter, cp1 and cp2 input will operate in the same way as the count input (cp1) of up (increment) mode. 2. must be greater than the minimum signal width and must be at least 1/2 the minimum signal width. if they are less, a count error of 1 may occur. minimum signal width: 16.7 ms (when maximum counting speed = 30 hz) 100 s (when maximum counting speed = 5 khz) 3. the meaning of the h and l symbols in the tables is explained below. must be at least 1/2 the minimum signal width. (see note 2.) 0 cp1 h l cp2 present value h l 0 1 2 4 3 5 prohibit a a a n cp1 h l cp2 present value h l 0 n ? 1 n ? 2 n ? 4 n ? 3 n ? 5 a a prohibit a 0 *cp1 h l cp2 present value h l 0 1 2 4 3 5 a a prohibit a n *cp1 h l cp2 present value h l 0 n ? 1 n ? 2 n ? 4 n ? 3 n ? 5 a a prohibit a 0 cp1 h l cp2 present value h l 0 1 2 2 2 1 3 3 a a a 0 cp1 h l cp2 present value h l 0 1 2 2 2 11 3 3 a b symbol input method no-voltage input (npn input) voltage input (pnp input) h short-circuit 4.5 to 30 vdc l open 0 to 2 vdc 0 cp1 h l cp2 present value h l 0 1 2 2 2 1 3 3 b b b b b
22 h7cx-a @ -n counter input/output mode settings i/o functions for counter operation if a 1-stage model or 2-stage model is incorrect ly used as twin counter, the operation for output 2 will be performed. when using a 2- stage model as a 1-stage preset counter, total and preset counter, or dual counter, out1 and out2 turn on and off simultaneously. input mode operation after count completion up down up/down a, b, c output mode setting n the outputs and present value display are held until reset/reset 1 is input. f the present value display continues to increase/decrease. the outputs are held until reset/reset 1 is input. c as soon as the count reaches sv, the present value display returns to the reset start status. the present value display does not show the present value upon count- up. the outputs repeat one- shot operation. out1 self-holding output turns off after the out2 one-shot output time. the out1 one-shot output time is independent of out2. r the present value display returns to the reset start status after the one-shot output time. the outputs repeat one- shot operation. out1 self-holding output turns off after the out2 one-shot output time. the out1 one-shot output time is independent of out2. k-1 the present value display continues to increase/decrease. out1 self-holding output turns off after the out2 one-shot output time. the out1 one-shot output time is independent of out2. self-holding output self-holding output one-shot output from out1 one-shot output from out2 (the one-shot output time can be set in the range 0.01 to 99.99s.) reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 999999 0 reset/ reset 1 out1 out2 set value 2 set value 1 999999 0 reset/ reset 1 out1 out2 set value 2 set value 1 999999 0 reset/ reset 1 out1 out2 set value 2 set value 1 999999 0 reset/ reset 1 out1 out2 set value 2 set value 1
h7cx-a @ -n 23 counter note: 1. the full scale (fs) for h7cx 4-digit models is 9999. 2. when the present value reaches 999999, it returns to 0. 3. counting cannot be performed during reset/reset 1 input. 4. if reset/reset 1 is input while one-shot output is on, one-shot output turns off. 5. if there is power failure while output is on, output wi ll turn on again when the power supply has recovered. for one-shot output, output will turn on ag ain for the duration of the output time setting once the power supply has recovered. 6. do not use the counter function in applic ations where the count may be completed (again) while one-shot output is on. 7. the setting range is 0 to 999,999 (0 to 9,999 for 4-digit models). self-holding output self-holding output one-shot output from out1 one-shot output from out2 (the one-shot output time c a set in the range 0.01 to 99. 9 input mode operation after count completion up down up/down a, b, c output mode setting p the present value display does not change during the one-shot output time period, but the actual count returns to the reset start status. the output will return to one-shot mode. the outputs repeat one-shot operation. out1 self-holding output turns off after the out2 one-shot output time. the out1 one-shot output time is independent of out2. q the present value continues to increase/ decrease for the one- shot output time, but returns to the reset start status after the one-shot output time has elapsed. the outputs repeat one-shot operation. out1 self-holding output turns off after the out2 one-shot output time. the out1 one-shot output time is independent of out2. a the present value display and out1 self-holding output is held until reset/reset 1 is input. out1 and out2 are independent. 0 reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 reset/ reset 1 out1 out2 999999 set value 2 set value 1
24 h7cx-a @ -n counter note: 1. counting cannot be performed during reset/reset 1 input. 2. if reset/reset 1 is input while one-shot output is on, one-shot output turns off. 3. if there is power failure while output is on, output wi ll turn on again when the power supply has recovered. for one-shot output, output will turn on again for the duration of the output time setting once the power supply has recovered. 4. do not use the counter function in applications where t he count may be completed (again) while one-shot output is on. 5. the set value is from ? 99999 to 999999. one-shot output self-holding output instantaneous (equals) output (the one-shot output time can be set in the range 0.01 to 99.99s.) input mode operation after count completion up/down a, b, c output mode setting k-2 the display continues to increase/ decrease until the overflow or underflow value is reached. one-shot output only. d the display continues to increase/ decrease until the overflow or underflow value is reached. the outputs are on while the count is equal. l the display continues to increase/ decrease until the overflow or underflow value is reached. out1 is held while the present value is less than or equal to set value 1. out2 is held while the present value is greater than or equal to set value 2. h the display continues to increase/ decrease until the overflow or underflow value is reached. out1 is held while the present value is greater than or equal to set value 1. out2 is held while the present value is greater than or equal to set value 2. * h mode is available only when using a 6- digit model as a 2-stage counter. 0 ? 99999 reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 ? 99999 reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 ? 99999 reset/ reset 1 out1 out2 999999 set value 2 set value 1 0 ? 99999 reset/ reset 1 out1 out2 999999 set value 2 set value 1
h7cx-a @ -n 25 counter total and preset counter operation the h7cx has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value. batch counter operation the h7cx has a batch counter, separate from the 1-stage preset counter , for counting the number of times the count has been com pleted. note: 1. the batch count value is held at 0 during batch counter reset input. 2. if the batch count set value is 0, batch count will be performed but there will be no batch output. 3. the batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models). 4. once batch input has been turned on, it will return to the on state after power interruptions. 5. if the batch count set value is changed from a value that is gr eater than the batch count value to one that is less, batch outp ut will turn on. 6. after batch output turns on, the on state will be held even if the batch count set value is changed to a value greater than the batch count value. dual counter operation using the dual counter allows the count fr om 2 inputs to be added or subtracted and the result displayed. it is possible to spe cify a set value for which output turns on when the set value matches the added or subtracted result. note: 1. counting is not possible for cp1 during reset 1 input. cp2 will not be affected. the dual count value will be calculated based on a cp1 present value of 0. 2. counting is not possible for cp2 during reset 2 input. cp1 will not be affected. the dual count value will be calculated based on a cp2 present value of 0. 3. the counting range for the dual count value is ? 99,999 to 999,999 (0 to 9,999 for 4-digit models). the counting ranges for the cp1 present value and cp2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). if a present value exceeds 999,9 99 (9,999 for 4-digit models), ffffff (ffff for 4-digit models) will be displayed to indicate a n overflow, and all counting will stop.  the total counter continues to count the total accumulated value when the present value is reset using reset/reset 1 input (reset key).  the total count value is reset when the total reset/reset 2 input is turned on. if the reset key is pressed while the total count value is displayed, the total count value is reset. the present value is also reset at this time.  the counting range of the total counter is ? 99,999 to 999,999 ( ? 999 to 9,999). the total count value returns to 0 when it reaches the full scale limit.  the batch counter continues after count completion.  batch output is held until batch counter reset is input.  when the batch counter reset input is turned on, the batch count value is reset, and batch output turns off.  if the reset key is pressed while the batch count value is displayed, the batch count value is reset and batch output turns off. the present value is also reset at this time.  the count value can be incremented and decremented. the batch count is only incremented.  the maximum counting speed for batch counter operation is 5 khz. the batch counter counts the number of times the count reaches the set value.  the operation after count completion for the dual counter value is determined by the output mode.  the cp1 present value is reset when reset 1 input is turned on. the cp2 present value is reset when reset 2 input is turned on.  if the reset key is pressed while the dual count value, cp1 present value, or cp2 present value is displayed, all of the present values are reset and outputs turn off. at this time, counting is not possible for cp1 or cp2 inputs. reset/reset 1 total reset or reset 2 0 present value total count value 0 999999 note: the full scale (fs) for h7cx 4-digit models is 9999. 0 batch count set value sub-display 0 out1 (batch output) batch count value (main display) 1 2 reset 1 set value out2 present value note: the above is for when the output mode is c. reset 2 (batch counter reset) reset 1 (cp1 reset) reset 2 (cp2 reset) dual count set value dual count value 0 cp1 present value 0 cp2 present value 0 out1, out2 note: the above is for when the output mode is n. 0 0 0 reset 1 (cp1 reset) reset 2 (cp2 reset) dual count set value dual count value cp1 present value cp2 present value out1, out2 note: the above is for when the output mode is k-2. sub mode can be used only when k-2, d, l, or h is selected as the output mode with 6-digit models. (1) dual count calculating mode = add dual count value = cp1 pv + cp2 pv (2) dual count calculating mode = sub dual count value = cp1 pv ? cp2 pv
26 h7cx-a @ -n counter twin counter operation two independent counters are built in. note: 1. only 2-stage models 2. increment mode only for counters 1 and 2. 3. the settings for prescaling and the decimal point are used by both counter 1 and 2. reset function list i/o functions for counter operation  the following table shows the delay from when the present value passes the set value until the output is produced. actual measurements in n and k-2 modes (reference values) note: the above times may vary slightly dependi ng on the mode or operating conditions. counter 1 counter 2 counter input cp1 cp2 reset input reset 1 reset 2 present value display and setting reset key only counters appearing on the display will be reset. function 1-stage/2- stage preset counter total and preset counter batch counter dual counter twin counter screen dis- played in run mode present value/ set value (1, 2) present value/set value total count value present value/set value batch count value/batch count set value dual count value/dual count set value cp1 present value/cp2 present value present value 1/set value 1 present value 2/set value 2 reset/reset 1 present value and output reset. present value and output reset. present value and output reset. only the cp1 present value is reset. only the cp1 present value is reset. total reset or reset 2 no effect only the total count value is reset. batch count value and batch output reset. only the cp2 present value is reset. only the cp2 present value is reset. reset key present value and output reset. present value and output reset. present value, total count value, and output reset. present value and output reset. present value, batch count value, output and batch output reset. cp1 present value, cp2 present value, dual count value, and output reset. cp1 present value reset cp2 present value reset control output type max. counting speed output delay time contact output 30 hz 16.5 to 24.0 ms 5 khz 3.7 to 5.6 ms transistor output 30 hz 12.0 to 20.0 ms 5 khz 0.2 to 0.55 ms counter 1 present value counter 1 set value counter 2 present value counter 2 set value counter 1 display counter 2 display switched with the key.
h7cx-a @ -n 27 tachometer setting procedure guide tachometer operation after making dip switch settings for basic operations , advanced functions can be added using the operation keys. for details, refer to page page 28. step1 the h7cx is factory-set to the 2-stage counter configuration (1-stage counter configuration for h7cx-au @ -n models). enter configuration selection mode using the following chart and set the tachometer mode. off on off on off off on on upper/lower limit output range output upper limit output lower limit output off on off on off off on on off 2 times 4 times 8 times --- --- --- step2 key-protect switch disabled enabled refer to the table on the right. 30 hz 10 khz dip switch settings counting speed tachometer output mode average processing input selection npn pnp note: all pins are factory-set to off. step3 set the basic parameters. (if the desired i/o mode is not listed below or to set all parameters using the front panel keys, perform , below.) note: can be performed first, followed by . item off on step2 step1 hold down for 1 s min. switch from 2cnt (2-stage preset counter mode) to taco (tachometer mode) using the u key. run mode power on 1 + hold down for 1 s min. 1 + configuration selection mode refer to the table on the right. tachometer output mode pin 4 pin 3 average processing pin 6 pin 5 1 2 3 4 5 6 7 8 ? when setting functions using the dip switch, be sure to set pin 1 of the dip switch to on. ? dip switch settings are effective when the power is turned on again. (perform dip switch settings while the power is off.) be sure to set pin 1 to on. off on 12345678
28 h7cx-a @ -n tachometer step3 (no decimal point) (one digit after decimal point) (two digits after decimal point) (three digits after decimal point) (four digits after decimal point) (30 hz) (10 khz) (99.9 s) (0.0 s) (999.9 s) (0.1 s) (99.999) (1.000) (0.001) (no average processing) (average of 2 measurements) (average of 4 measurements) (average of 8 measurements) (average of 16 measurements) (simple averaging) (moving average) (lo) (hi) (lo) (hi) (area) (hi-hi) (lo-lo) (hi-lo) hilo 30hz --.---- 0.001 smp mv off 0.1 999.9 0.0 99.9 248 16 1.000 99.999 area hihi lolo (error) (absolute ratio) (1 input) (2 inputs) f1 f2 f3 f4 (error ratio) f5 lo hi lo hi run mode power on function setting mode *1 *1 set tachometer output modes 1 and 2 using the u key. 3 s min. *2 3 s min. *1 parameters that cannot be set with the dip switch are set with the operation keys on the front panel. change to function setting mode. counting speed (cnts) tachometer output mode (totm) auto-zero time (aut00) startup time (stmr) average processing (avgn) decimal point position (dp) the characters displayed in reverse video are the default settings. when performing settings with operation keys only, set pin1 of the dip switch to off (factory setting). if pin 1 of the dip switch is set to on, the setting items indicated by will not be displayed. to next page from next page prescale value (pscl) averaging method (avgt)  set the tachometer input mode using the u key. tachometer output mode 1 (to1m) * displayed only when the tachometer input mode is f2 (2 inputs). function setting mode *1 if the mode is switched to the function setting mode during operation, operation will continue. *2 changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. also, when settings are changed, the counter is reset (measured value initialized and outputs turned off) on returning to run mode. tachometer input mode (tinm)  set the tachometer output mode using the u key.  set the counting speed using the u key.  set the decimal point position using the u key.  set each digit using the individual u key. note: ?--.----? will be displayed when pulse width measurement is set or when the display unit is set to seconds.  set the averaging method using the u key.  set the number of averaging times using the u key.  set each digit using the individual u key.  set each digit using the individual u key. tachometer output mode 2 (to2m) note: even if 10 khz is selected when the tachometer input mode is f2 to f5, the counting speed will be 5 khz. for details on operations and display in run mode, refer to page page 33.
h7cx-a @ -n 29 tachometer (enabled) (disabled) (red) (green) (orange) (red-green) (green-red) (red-orange) (orange-red) (green-orange) (orange-green) (pnp input) (npn input) ( 19.99 s) ( 0.00 s) 9999 0 9999 0 (99999 ) (0 ) 99999 0 (999999 ) 999999 on off grn red org r-g g-r r-o o-r g-o o-g npn pnp 19.99 0.00 (9999 1000 times) (0 1000 times) (9999 1000 times) (0 1000 times) *2 set each digit using the individual u keys. from previous page to previous page  set the npn/pnp input mode using the u key. output 1 (out1) on count alarm set value output 2 (out2) on count alarm set value output 1 (out1) on count monitor value function setting mode npn/pnp input mode (imod) display color (colr) note: the monitor value is only displayed. it cannot be set. output 2 (out2) on count monitor value peak/bottom hold enabled (dhld) output hysteresis (hys) output off delay (offd) set value upper limit (sl-h)  set the display color using the u key.  enable or disable the peak/bottom hold using the u key.  set the output hysteresis using the u key. note: the measurement value after prescaling is set.  set each digit using the individual u key.  set each digit using the individual u key. note: the monitor value is only displayed. it cannot be set. ( 1 ) 1 (pulse width measurement) (pulse cycle measurement) ( s) ( hz) (cont (10 ms min.)) ( 200 ms) ( kp-1) ( kp-2) ( kp-3) ( kp-4) ( kp-5) ( kp-6) ( kp-7) phas s hz cont 200ms kp-1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 *2 key protect level (kypt) pulse cycle measurement/ pulse width measurement (calm) display unit (unit) measurement interval (intv) output on count alarm set value/monitor value  set the key protect level using the u key.  set pulse cycle measurement or pulse width measurement using the u key.  set the display unit using the u key. note: displayed only when pulse cycle measurement is used.  set each digit using the individual u key. note: displayed only if the measurement speed is 10 khz when pulse cycle measurement is used. (on) (off) on off output allocation change note: displayed only for "-au @ " models. off : output 1 = 12, 13, output 2 = 3, 4, 5 on: output 1 = 3, 4, 5, output 2 = 12, 13 the numbers are the terminals numbers.
30 h7cx-a @ -n tachometer explanation of functions tachometer operation items marked with stars can be set using the dip switch. tachometer input mode ( tinm ) set the count input mode to one of the following: 1 input ( f1 ), 2 inputs ( f2 ), error ( f3 ), absolute ratio ( f4 ), or error ratio ( f5 ). tachometer output mode ( totm ) set the output method for control output based on the comparison value. upper and lower limit (hi-lo), area (area), upper limit (hi-hi), and lower limit (lo-lo) can be set. (for details on the output modes, refer to output mode settings and operation on page page 34.) counting speed ( cnts ) set the maximum counting speed (30 hz/10 khz) for cp1 input. if contacts are used for input signal s, set the counting speed to 30 hz. processing to eliminate chatteri ng is performed for this setting. decimal point position ( dp ) decide the decimal point position for the measurement value, out1 set value, and out2 set value. prescale value ( pscl ) it is possible to display the rate of rotation or the speed of a device or machine to which the h7cx is mount ed by converting input pulses to a desired unit. if this prescaling function is not us ed, the input frequency (hz) will be displayed. it is also possible to specify time (seconds) as the display value. refer to display unit on page page 31 for details. the relationship between display and input is determined by the following equation. set the prescale value according to the unit to be displayed. displayed value = f f: input pulse frequency (number of pulses in 1 second) : prescale value (1) displaying rotation rate n: number of pulses per revolution example: to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@ . @ rpm: 1. set the decimal point position to 1 decimal places. 2. using the formula, set the prescale value ( ) to 1/n 60 = 60/5 = 12. (2) displaying speed n: number of pulses per revolution d: diameter of rotating body (m) d: circumference (m)  observe the following points when setting a prescale value. set the set value to a value less than {maximum countable value ? prescale value}. example: if the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 ? 1.25). if the set value is set to a value great er than this, output will not turn on. * output will turn on, however, if a present value overflow occurs (ffffff or ffff}. averaging method ( avgt ) (only for tachometer operation) a simple average or moving average can be selected for the averaging. with the moving average method, the average of the measurement values is displayed eac h sampling cycle, in contrast to a simple average, with which the the average of the set number of samples is displayed. number of averaging times ( avgn ) flickering display and output chattering can be prevented using average processing. average proces sing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 time s, 8 times, or 16 times. the measurement cycle will be equal to the sampling cycle multiplied by the average processing setting (i.e., the number of times). average processing enables stable disp lays even for fluctuating input signals. set the optimum number of times for the application. auto-zero time ( auto0 ) the display can be force-set to 0 if there is no pulse for a certain period of time. this time is called the auto-zero time. set the auto-zero time to a time slightly longer than the estimated interval between input pulses. accurate measurement is not possible if the auto-zero time is set to a time shorter than the input pulse cycle. setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turni ng on. the auto-zero time is not applied to pulse width measurements. startup time ( stmr ) to prevent undesired outputs resulting from unstable inputs immediately after the power supply is turned on, it is possible to prohibit measurement for a set per iod of time, the startup time. it can also be used to stop meas urements and disable outputs until the rotating body reaches the normal ra te of rotation, after the power supply to the h7cx and rotating body are turned on at the same time. input mode input internal processing application 1 input count 1 none operation with only one input. 2 inputs counts 1 and 2 none operation with two independent inputs. error counts 1 and 2 count 1 input ? count 2 input measuring the difference between two inputs (error in number of revolutions). absolute ratio counts 1 and 2 count 1 input count 2 input measuring the ratio of two inputs (ratio of number of revolutions). error ratio counts 1 and 2 (count 1 input ? count 2 input) count 2 input measuring the ratio of error for two inputs (measuring the error ratio of number of revolutions). display unit prescale value ( ) rpm 1/n 60 rps 1/n display unit prescale value ( ) m/min d 1/n 60 m/s d 1 /n d: diameter of rotating body (m) note: if the prescale value setting is incorrect, a counting error will occur. check that the settings are correct before using this function. startup time display time comparison value (lower limit) output (lower limit) power supply
h7cx-a @ -n 31 tachometer npn/pnp input mode ( imod ) select either npn input (no-vo ltage input) or pnp input (voltage input) as the input format. when using a two-wire sensor, sele ct npn input. the same setting is used for all external inputs. for details on input connections, refer to input connections on page page 9. display color ( colr ) set the color used for the measurement value. *1. if the tachometer output mode is set to area, however, the measured value is displayed in red when control output 1 is off and in green when control output 1 is on. *2. if the tachometer output mode is set to area, however, the measured value is displayed in green when control output 1 is off and in red when control output 1 is on. *3. if the tachometer output mode is set to area, however, the measured value is displayed in red when control output 1 is off and in orange when control output 1 is on. *4. if the tachometer output mode is set to area, however, the measured value is displayed in orange when control output 1 is off and in red when control output 1 is on. *5. if the tachometer output mode is set to area, however, the measured value is displayed in green when control output 1 is off and in orange when control output 1 is on. *6. if the tachometer output mode is set to area, however, the measured value is displayed in orange when control output 1 is off and in green when control output 1 is on. peak/bottom hold enabled ( dhld ) this function records the peak and bottom (i.e., minimum) after counting starts (after turning on the power supply or changing the configuration selection mode or func tion setting). the peak value is also held when the power supply is interrupted. output hysteresis ( hys ) this setting can be used to prevent output chattering if the measurement value fluctuates slightly near the set value. the measurement value after prescaling is set. output off delay ( offd ) this function delays the timing for tu rning off comparative output by a certain time. the on time can be held for the set time if the comparative result changes in a short time. operation will continue and outputs will not change when holding the value. set value upper limit ( pl-h ) set the upper limit for the set value when it is set in run mode. the limit can be set to between 1 and 999999. output allocation ( otst ) when using an h7cx-au @ -n model as 2-stage counter, each output can be flexibly allocated to either stage 1 or 2. the transistor output can be allocated to sv1 and the contact output to sv2 or vice verse, as in the following tables. h7cx-au-n/-aud1-n h7cx-ausd1-n key protect level ( kypt ) set the key protect level. refer to key protect level on page page 36. pulse cycle measurement/p ulse width measurement ( calm ) set the measurement mode to pulse cycle measurement or pulse width measurement. with pulse cycle measurement, the number of pulse cycles that occur in 1 s is measured. with pulse width measurement, t he on time for one pulse is measured. an input off period of at least 20 ms is required for pulse width measurement. if there is no input pulse duri ng pulse width measurement, the previously measured value will be held. display unit ( unit ) when pulse cycle measurement is us ed, set the display unit to hz (hertz) or s (seconds). counting interval ( intv ) if the measurement speed is 10 khz when pulse cycle measurement is used, set the measurement interval to 200 ms or cont (10 ms min.). control output off control output on red red (fixed) grn green (fixed) org orange (fixed) r-g *1 measured value is displayed in red when both control outputs 1 and 2 are off. measured value is displayed in green when either control output 1 or control output 2 is on. g-r *2 measured value is displayed in green when both control outputs 1 and 2 are off. measured value is displayed in red when either control output 1 or control output 2 is on. r-o *3 measured value is displayed in red when both control outputs 1 and 2 are off. measured value is displayed in orange when both control outputs 1 and 2 are off. o-r *4 measured value is displayed in orange when both control outputs 1 and 2 are off. measured value is displayed in red when both control outputs 1 and 2 are off. g-o *5 measured value is displayed in green when both control outputs 1 and 2 are off. measured value is displayed in orange when both control outputs 1 and 2 are off. o-g *6 measured value is displayed in orange when both control outputs 1 and 2 are off. measured value is displayed in green when both control outputs 1 and 2 are off. output 1 output 2 off transistor (12-13) contact (3, 4, 5) on contact (3, 4, 5) transistor (12-13) output 1 output 2 off transistor (12-13) transistor with diode (3, 4, 5) on transistor with diode (3, 4, 5) transistor (12-13) outx1 outy2 display value comparison value 2 hysteresis hysteresis comparison value 1 set the hysteresis for when the output turns off.
32 h7cx-a @ -n tachometer on count alarm set values for outputs 1 and 2 (out1 and out2) ( on1a and on2a ) set the on count alarm values for the outputs 1 and 2. the limit can be set to between 0 1000 (0 times) and 9999 1000 (9,999,000 times). only the underli ned values are set. the alarm will be disabled if 0 is set. if the total on count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the timer to indicate that the output on count alarm value was exceeded. refer to self-diagnostic function on page page 36 for information on the e3 display. on count monitor values fo r outputs 1 and 2 (out1 and out2) ( on1c and on2c ) the monitor value for output 1 or 2 is only displayed. it cannot be set. the output on count will be 1,000 times the displayed value.
h7cx-a @ -n 33 tachometer operation in run mode tachometer operation bottom hold value peak hold value bottom hold value 1 peak hold value 1 bottom hold value 2 peak hold value 2 measurement value 1 comparison value 1 measurement value 2 comparison value 2 measurement value  set each digit using the individual u keys. displayed when the input mode is not 2 inputs.  measurement value displays the currently measured value.  comparison value 1/comparison value 2 set comparison value 1 and comparison value 2. the measurement value is compared to comparison value 1 and comparison value 2 and output is made according to the selected output mode. *3 *1 measurement value 1 for the 2-input input mode. *2 measurement value 2 for the 2-input input mode. *3 peak/bottom hold enabled displayed for the 2-input input mode.  peak/bottom hold value the peak (maximum) and bottom (minimum) values are displayed after counting starts.  peak/bottom hold value 2 peaks (maximums) 1 and 2 and bottoms (minimums) 1 and 2 are displayed after counting starts. *1 *2 note: the held values will be initialized when the reset key (hold key) or reset 1 input is turned off while peak/bottom hold values 1 and 2 are being displayed. (the reset 2 input operates in the same way if the input mode is set to 2-input mode.)
34 h7cx-a @ -n output mode setting and operation tachometer operation input mode setting output mode setting operation 1 input error absolute ratio error ratio upper and lower limit (hi-lo) area (area) upper limit (hi-hi) lower limit (lo-lo) 2 inputs upper limit (hi) lower limit (lo) out1 out2 measurement value (upper-limit) comparison value 2 (lower-limit) comparison value 1 on condition for out1: measurement value comparison value 1 on condition for out2: measurement value comparison value 2 out1 out2 measurement value comparison value 2 comparison value 1 condition comparison value 1 comparison value 2 measurement value 1 > comparison value 2 on condition for out1 comparison value 1 measurement value comparison value 2 comparison value 2 measurement value comparison value 1 on condition for out2 measurement value < comparison value 1 or measurement value > comparison value 2 measurement value < comparison value 2 or measurement value > comparison value 1 out1 out2 measurement value (upper-limit) comparison value 2 (lower-limit) comparison value 1 on condition for out1: measurement value comparison value 1 on condition for out2: measurement value comparison value 2 out1 out2 measurement value (upper-limit) comparison value 2 (lower-limit) comparison value 1 on condition for out1: measurement value comparison value 1 on condition for out2: measurement value comparison value 2 out1 cp1 display value comparison value 1 output 1 out2 cp2 display value comparison value 2 output 2 on condition for output 1: cp1 present value (display value) comparison value 1 on condition for output 2: cp2 present value (display value) comparison value 2 out1 cp1 display value comparison value 1 output 1 out2 cp2 display value comparison value 2 output 2 on condition for output 1: cp1 present value (display value) comparison value 1 on condition for output 2: cp2 present value (display value) comparison value 2
h7cx-a @ -n 35 switching between preset counter, total an d preset counter, batch counter, dual counter, twin counter, and tachometer operation select which h7cx configuration is used (i.e., preset counter, total and preset co unter, batch counter, dual counter, twin coun ter, or tachometer) in configuration selection mode. the h7cx is also equipped with a dip switch monitor function, a convenient function that enables the settings of the dip switch pins to be confirmed using the display on the front of the h7cx. hold function the measurement value (display value) and out put are sustained while the hold input is on. note: the output will maintain the current status when the hold key is pressed. example: output mode setting operation lower limit 1 + 1 1 rst bcnt dcnt taco twn 1cnt 2cnt tcnt key key key key ?indicates that dip switch pin 8 is on. ?indicates that dip switch pin 7 is off. ?indicates that dip switch pin 6 is on. ?indicates that dip switch pin 5 is off. ?indicates that dip switch pin 4 is on. ?indicates that dip switch pin 3 is off. ?indicates that dip switch pin 2 is on. ?indicates that dip switch pin 1 is on. *the configurations that can be selected depend on the model. press the key for 1 s min. *1 when the mode is changed to configuration selection mode, the present value is reset, outputs turn off, and counting (measur ing) stops. *2 setting changes made in configuration selection mode are enabled when the mode is changed to run mode. if the configuration is changed, the set value (or set value 1 and set value 2), comparison value 1 and comparison value 2 are initialized. power on example configuration selection note dip switch monitor (dip) convenient *2 *1 *this display is possible only when dip switch pin 1 (dip switch settings enable/disable) is set to on (enable). select the configuration using the ud key. run mode configuration selection mode 1 1 to change the mode to configuration selection mode, hold down the key for 1 s min. with the key held down. the mode will not change if the key is pressed first. (1-stage preset counter) (2-stage preset counter) (total and preset counter) (batch counter) (dual counter) (twin counter) (tachometer) note: by default, the h7cx is set to the 1-stage preset counter configuration. (two-stage models are set to the 2-stage preset counter configuration.) confirm the status of dip switch pins 1 to 8 using the ud key. off on 12345678 out display value hold input* (reset key) comparison value (lower limit) sustained display value sustained output actual input
36 h7cx-a @ -n key protect level it is possible to prevent setting errors by prohibiting the use of certain operation ke ys by specifying the key protect level ( kp-1 to kp-7) when the key-protect switch is set to on. the key protect level is set in the function setting mode. the ke y protect indicator is lit when the key-protect switch is on. * changing mode to configuration selection mode or function setting mode. self-diagnostic function the following displays will appear if an error occurs. *1. displays for 4-digit models are given in parentheses. *2. this includes times when the life of the eeprom has expired. *3. this occurs if the present value or total count value falls below ? 99999 ( ? 999 for 4-digit models). *4. this occurs in the following cond itions if the present value (i.e., measurement value) exceeds 999999 (9999 for 4-digit models). ? for output modes k-2, d, l, or h ? dual counter or tachometer operation is used. *5. display flashes.(1-second cycles) *6. this does not apply when tachometer operation is used. *7. this is displayed if the alarm value setting for either of the two outputs is exceeded if a model with two outputs is used.the total on count will not be cleared by using the reset key. *8. the normal display and e3 will appear alternately. when the reset key is pressed, e3 will not be displayed even if the alarm set value is exceeded. (monitoring is possible, however, bec ause the counter will continue without the output on count being cleared.) level description details changing modes* switching display during operation reset key up/down keys kp-1 (default setting) invalid valid valid valid kp-2 invalid valid invalid valid kp-3 invalid valid valid invalid kp-4 invalid valid invalid invalid kp-5 invalid invalid invalid invalid kp-6 invalid invalid valid valid kp-7 invalid invalid invalid valid *factory-set to off on (enable) off (disable) * key protect indicator main display sub-display description output status correction method set value after reset ----- ( ---- )*1*5 no change present value underflow*3 no change either press the reset key or turn on reset input. no change fffff ( ffff )*1*5 no change present value overflow*4 no change either press the reset key or turn on reset input.*6 no change e1 not lit cpu error off either press the reset key or reset the power supply. no change e2 not lit memory error (ram) off turn on the power again. no change e2 sum memory error (eeprom)*2 off reset key factory setting e3 *8 no change output counter overflow no change reset key*7 no change
h7cx-r @ -n 37  tachometer-only model (din 48 48) for the h7cx (supports display and alarm outputs for numbers of rotations, speed, and flow rate.)  socket design allows either flush or surface mounting.  ?-w? models added for control with two independent measurements.  operation in any of the four followin g modes is possible with the same unit: upper and lower limit , upper limit, lower limit, and area.  equipped with auto-zero time, average processing, and startup time functions. specifications ratings *1. do not use the output from an inverter as the power supply. the ripple must be 20% maximum for cc power. *2. the display is lit only when the power is on. nothing is displayed when power is off. h7cx-r @ -n tachometer classification tachometer item model h7cx-r11 @ -n h7cx-r11w @ -n input mode 1 input only 2 inputs only ratings power supply voltage *1  100 to 240 vac, 50/60 hz  12 to 24 vdc or 24 vac, 50/60 hz operating volt- age fluctuation range 85% to 110% of rated supply voltage (90% to 110% at 12 to 24 vdc) power consump- tion approx. 9.4 va at 100 to 240 vac, approx. 7.2 va/4.7 w at 24 vac/12 to 24 vdc, approx. 3.7 w at 12 to 24 vdc mounting method flush mounting or surface mounting external connections 11-pin socket degree of protection iec ip66, ul508 type 4 (indoors) for panel surface only and when y92s-29 waterproof packing is used input signals count and hold count 1 and count 2 pulse measurement method tachometer mode (cycle measurement) amd-compatible mode (continuous measurement) tachometer mode (cycle measurement) maximum counting speed 30 hz 10 khz --- 5 khz minimum input signal width --- 10 ms 1 ms --- measuring ranges 0.01 hz to 30.00hz 0.01 hz to 10 khz 0.026 to 999999 s 0.003 to 999999 s 0.01 to 5k hz sampling cycle 200 ms min. continuous measurement (minimum interval of 10 ms) 200 ms min. display refresh cycle  input pulse of 5 hz min. averaging not used: 200 ms averaging used: 200 multiplied by the averaging setting (ms)  input pulse of less than 5 hz using averaging: two times the maximum input pulse cycle using averaging: two times the maximum of the inpu t pulse cycle multiplied by the averaging setting. measuring accuracy 0.1% fs 1 digit max. (at 23 5 c) output mode hi-lo, area, hi-hi, lo-lo hi-hi, lo-lo auto-zero time 0.1 to 999.9 s (in tachometer mode) startup time 0.0 to 99.9 s averaging simple averaging/moving averaging selectable, number of times: off, 2, 4, or 8 times prescaling function 0.001 to 99.999 (in tachometer mode) decimal point adjustment rightmost 3 digits --- sensor waiting time 290 ms max. (control output is turned off and no input is accepted during sensor waiting time.) input input method no-voltage input impedance when on: 1 k ? max. (leakage current: 12 ma when 0 ? ) on residual voltage: 3 v max. impedance when off: 100 k ? min. voltage input high (logic) level: 4.5 to 30 vdc low (logic) level: 0 to 2 vdc (input resistance: approx. 4.7 k ? ) no-voltage input/voltage input (switchable) hold input minimum input signal width: 20 ms --- external power supply 12 vdc ( 10%), 100 ma * refer to safety precautions (common) on page page 52 for details. control output contact output: 3 a at 250 vac/30 vdc, resistive load (cos =1) minimum applied load:10 ma at 5 vdc (failure level: p, reference value) display*2 7-segment, negative transmissive lcd character height present value: 10 mm (red), comparison value: 6 mm (green) digits 6 digits (0 to 999999) memory backup eeprom (overwrites: 100,000 times min.) that can store data for 10 years min. operating temperature range ? 10 to 55 c ( ? 10 to 50 c if counter/tachometers are mounted side by side) (with no icing or condensation) storage temperature range ? 25 to 70 c (with no icing or condensation) operating humidity range 25% to 85% case color black (n1.5)
38 h7cx-r @ -n characteristics i/o functions * refer to page page 50 for details on the hold function.  the following table shows the del ay from when the reset signal is input until the output is turned off. (reference values) *see life-test curve (reference values) on the right. applicable standards * the following safety standards apply to the h7cx-r11 @ . cul (listing): applicable when an omron p2cf(-e) socket is used. cur (recognition): applicable when any other socket is used. insulation resistance 100 m ? min. (at 500 vdc) between current-carrying terminal and exposed non- current-carrying metal parts, and between non-continuous contacts dielectric strength 2,000 vac, 50/60 hz for 1 min between current-carrying metal parts and non-current- carrying metal parts 2,000 vac (for 100 to 240 vac), 50/60 hz for 1 min between power supply and input circuit (1,000 vac for 24 vac/12 to 24 vdc) 2,000 vac 50/60 hz for 1 min between control output, power supply, and input circuit 1,000 vac, 50/60 hz for 1 min bet ween non-continuous contacts impulse withstand voltage 3.0 kv (between power terminals) for 100 to 240 vac, 1.0 kv for 24 vac/12 to 24 vdc 4.5 kv (between current-carrying termina l and exposed non-current-carrying metal parts) for 100 to 240 vac, 1.5 kv for 24 vac/12 to 24 vdc noise immunity 1.5 kv (between power terminals) 600 v (between input terminals) square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) static immunity destruction: 15 kv, malfunction: 8 kv vibration resistance destruction 10 to 55 hz with 0.75-mm single amplitude, each in three directions for 2 hours malfunction 10 to 55 hz with 0.35-mm single amplitude, each in three directions for 10 min shock re- sistance destruction 300m/s 2 each in three directions, three cycles malfunction 100m/s 2 each in three directions, three cycles life expectancy mechanical: 10,000,000 operations min. electrical: 100,000 operations min. (3 a at 250 vac, resistive load, ambient temperature condition: 23 c) * weight approx. 110 g (tachometer only) approved safety standards culus (or curus): ul508/csa c22.2 no. 14* conforms to en 61010-1 (iec 61010-1): pollution degree 2/overvoltage category ii, b300 pilot duty, 1/4 hp 120 vac, 1/3 hp, 240 vac, 3-a resistive load emc (emi) emission enclosure: emission ac mains: (ems) immunity esd: immunity rf-interference: immunity conducted disturbance: immunity burst: immunity surge: immunity voltage dip/interruption: en61326 en55011 group 1 classa en55011 group 1 classa en61326 en61000-4-2: 4 kv contact discharge (level 2); 8 kv air discharge (level 3) en61000-4-3: 10 v/m (amplitude-modulated, 80 mhz to 1 ghz) (level 3); 10 v/m (pulse-modulated, 900 mhz 5 mhz) (level 3) en61000-4-6: 10 v (0.15 to 80 mhz) (level 3) en61000-4-4: 2 kv power-line (level 3); 1 kv i/o signal-line (level 4) en61000-4-5: 1 kv line to lines (power and output lines) (level 2); 2 kv line to ground (power and output lines) (level 3) en61000-4-11: 0.5 cycle, 100% (rated voltage) life-test curve (reference values) resistive load inductive load a current of 0.15 a max. can be switched at 125 vdc (cos =1) (life expectancy: 100,000 operations) a current of 0.1 a max. can be switched if l/r=7 ms. (life expectancy: 100,000 operations) 1,000 700 500 300 100 70 50 load current (a) 01 2 34 30 vdc (cos =1) 250 vac (cos =1) no. of operations ( 10 3 ) 1,000 700 500 300 100 70 50 01 2 34 30 vdc (l/r=7 ms) load current (a) 250 vac (cos =1) no. of operations ( 10 3 ) inputs count, count 1, count 2 reads counting signals. hold  holds the measurement value and outputs.  the hold indicator is lit during hold.* outputs out outputs signals according to the specified output mode when a comparison value is reached. minimum reset signal width output delay time 1 ms 0.8 to 1.2 ms 20 ms 15 to 25 ms
h7cx-r @ -n 39 connections terminal arrangement * the hold function is the same whichever terminal is connected. terminals are not connected internally, and so do not use them for cross-over wiring. transistor output  the transistor output of the h7cx is isolated from the internal circuitry by a photocoupler, so t he transistor output can be used as both npn and pnp output.  the diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the h7cx. block diagram input circuits count and hold inputs 6 7 8 9 10 11 1 2 3 4 5 out 0 v ( + ) ( ? ) ( ? ) ( + ) sensor 12 vdc external power supply internal circui t count hold hold hold * * * h7cx-r11-n h7cx-r11d1-n 6 7 8 9 10 11 1 2 3 4 5 out1 out2 0 v ( + ) ( ? ) ( ? ) ( + ) sensor 12 vdc external power supply internal circui t internal circuit count 1 count 2 h7cx-r11w-n h7cx-r11wd1-n power for load + load power for load + load npn output pnp output power for load + counter inductive load no-voltage inputs (npn inputs) voltage inputs (pnp inputs) output circuit display circuit input circuits (basic insulation) (basic insulation) (basic insulation) internal control circuit power supply circuit key switch circuit internal circuit in +14v 1 k ? in approx. 4.7 k ? internal circuit
40 h7cx-r @ -n input connections the inputs of the h7cx-r are no-voltage (sho rt-circuit or open) inputs or voltage inputs. they are set for use as voltage input s at the time of delivery. no-voltage input s (npn inputs) no-voltage input signal levels note: the dc voltage must be 30 vdc max. voltage inputs (pnp inputs) voltage input signal levels open collector voltage output contact input dc two-wire sensor h7cx-r11 @ 35 47 6 plc or sensor 0 v for inputs hold count note: operates when the transistor turns on. h7cx-r11w @ 3 --- 6 sensor, etc. 0 v for inputs hold count note: operates when the transistor turns on. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 0 v for inputs hold count note: operate when the contact turns on. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 0 v for inputs hold count note: operates when the transistor turns on. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 no-contact input short-circuit level (transistor on)  residual voltage: 3 v max.  impedance when on: 1 k ? max. (the leakage current is approx. 12 ma when the impedance is 0 ? .) open level (transistor off)  impedance when off: 100 k ? min. contact in- put use contacts which can adequ ately switch 5 ma at 10 v. applicable two-wire sensor  leakage current: 1.5 ma max.  switching capacity: 5 ma min.  residual voltage: 3 vdc max.  operating voltage: 10 vdc no-contact input (npn tran sistor) no-contact input (pnp transistor) contact input sensor, etc. 0 v for inputs hold count note: operate when the transistor turns off. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 sensor, etc. 0 v for inputs hold count note: operate when the transistor turns on. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 0 v for inputs hold count note: operate when the contact turns on. h7cx-r11 @ 35 47 6 h7cx-r11w @ 3 --- 6 high level (input on): 4.5 to 30 vdc note: 1. the dc voltage must be 30 vdc max. 2. input resistance: approx. 4.7 k ? low level (input off): 0 to 2 vdc
h7cx-r @ -n 41 nomenclature dimensions (unit: mm) tachometers (factory setting) on (enable) (factory setting) off (disable) 10 mm 6 mm 6 4 5 7 8 9 10 11 2 3 1 1. hold indicator (orange) 2. key protect indicator (orange) 3. control output indicator (orange) 4. comparison value 1, 2 stage indicator (1-output models) (2-output models) lit when the key protect switch is on. (lit when the hold input or hold key is on. ) 7. mode key (used to switch mode and setting items.) 11. dip switch 1 6 5. present value (main display) 8. hold key 9. up keys to character height: 10 mm (red) (used to sustain the measurement value and output.) 6. comparison value (sub-display) character height: 6 mm (green) 10. key-protect switch 1st digit 6th digit display section operation keys switches character size for sub-display character size for main display off on 12345678 out out 1 2 63.7 14.4 6 44.8 44.8 48 48 dimensions without flush mounting adapter h7cx-r @ -n note: 1. the mounting panel thickness should be 1 to 5 mm. 2. to allow easier operation, it is recommended that adapters be mounted so that the gap between sides with hooks is at least 15 mm (i.e., with the panel cutouts separated by at least 60 mm). 3. it is possible to mount counters side by side, but only in the direction without the hooks. if counters/ tachometers are mounted side by side, however, water resistance will be lost. 60 min. 60 min. 15 min. 45 +0.6 ? 0 45 +0.6 ? 0 n side by side mounting a with y92a-48f1 attached. with y92a-48 attached. a=(48n ? 2.5) +1 ? 0 a=(51n ? 5.5) +1 ? 0 a={48n ? 2.5+(n ? 1) 4} +1 ? 0 panel cutouts panel cutouts are as shown below (according to din43700). 58 48 89.9 7.5 panel (51) y92s-29 (order separately) waterproof packing y92f-30 (order separately) flush mounting adapter p3ga-11 (order separately) rear surface connection socket dimensions with flush moun ting adapter (adapter and waterproof packing ordered separately) h7cx-r @ -n h7cx-r @ -n p2cf-11(-e) (order separately) front connecting socket 100.9 103.2* dimensions with front connecting socket h7cx-r @ -n * these dimensions vary with the kind of din track (reference value).
42 h7cx-r @ -n accessories (order separately) soft cover y92a-48f1 protecting the time r in environments subject to oil hard cover y92a-48 order the waterproof packing separately if it is lost or damaged. the waterproof packing can be used to achieve protection equivalent to ip66. (the waterproof packing will deteriorate, harden, and shrink depending on the application environment. to ensure maintaining the nema4 waterproof level, periodically replace the waterproof packing. the periodic replac ement period will depend on the application environment. you must confirm the proper replacement period. use 1 year or less as a gui deline. if the waterproof packing is not replaced periodically, the waterproof level will not be maintained.) it is not necessary to mount the waterproof packing if waterproof construction is not required. connection sockets refer to connection sockets on page page 13 for details. optional products for track mounting refer to optional products for track mounting on page page 14 for details. the h7cx's panel surface is wate r-resistive (conforming to ip @ 6, ul type 4x) and so even if drops of water penetrate the gaps between the keys, there will be no adv erse effect on internal circuits. if, however, there is a possibility of oil being present on the operator's hands, use the soft cover. the soft cover ensures protection equivalent to ip54 agains t oil. do not, however, use the h7cx in locations where it would co me in direct contact with oil. note: depending on the operating environment, the condition of resin or rubber products may deteriorate, or they may shrink or become harder. therefore, it is recommended that resin products be replaced regularly. y92f-45 use this adapter to install the counter/tachometer in a cutout previously made for a din 72 72 mm device (panel cutout: 68 68 mm). flush mounting adapter y92f-30 order a flush mounting adapter separately if the product is to be flush-mounted. waterproof packing y92s-29
h7cx-r @ -n 43 operating procedures parameters must be set using both the dip switch and the operation keys on the front panel. refer to the following for the detailed procedure. the settings made using the dip switch can be checked in the dip switch monitor mode. off on off on off off on on tachometer amd compatible tachometer amd compatible input mode *1 counting speed/ minimum input signal width output mode *2 average processing --- npn/pnp input mode --- --- npn pnp 30 hz 10 ms 10 khz *3 1 ms off on off on off off on on upper and lower limit area upper limit lower limit off on off on off off on on off (no average processing) 2 times 4 times 8 times step1 upper limit upper limit item off on counting speed/ minimum input signal width input mode pin 2 pin 1 output mode pin 4 pin 6 average processing pin 6 pin 5 1 2 3 4 5 6 7 8 set the basic parameters. refer to the table on the right. note: the characters displayed in reverse video are the default settings. refer to the table on the right. refer to the table on the right. *1. the setting is disabled (off) for the h7cx-r11w @ . *2. for the h7cx-r11w @ . refer to the table on the right. refer to the table on the right. output mode output mode note: the characters displayed in reverse video are the default settings. off on off on 3 4 item off on output mode pin 4 output mode pin 3 lower limit lower limit *3. for the h7cx-r11w @ , the counting speed will be 5 khz even if 10 khz is selected. off on 12345678 (factory setting)
44 h7cx-r @ -n (99.9 s) (0.0 s) (enabled) (disabled) (99999) (0) (19.99 s) (0.00 s) (999999) (1) (999.9 s) (0.1 s) kp-1 off on 0 99999 0.00 19.99 999999 1 kp-2 kp-3 kp-4 kp-5 kp-6 kp-7 0 9999 0 9999 0 9999 procedure for models other than ?-r11w @ ? models procedure for ?-r11w @ ? models (9999 1000 times) (0 1000 times) (kp-1) (kp-2) (kp-3) (kp-4) (kp-5) (kp-6) (kp-7) *1 note: not displayed in amd-compatible mode. *1 set each digit using the individual u key. note: the monitor value is only displayed. it cannot be set. output off delay (offd) output on count alarm set value/monitor value  set each digit using the individual u key. function setting mode auto-zero time (auto0) startup time (stmr) peak/bottom hold enabled (dhld) output hysteresis (hys) set value upper limit (sl-h) key protect level (kypt)  set each digit using the individual u key.  enable or disable peak/bottom hold using the u key.  set the output hysteresis using the u key.  set each digit using the individual u key. note: the measurement value after prescaling is set.  set each digit using the individual u key.  set the key protect level using the u key. output on count alarm set value output on count monitor value output 1 (out1) on count alarm set value output 2 (out2) on count alarm set value note: the monitor value is only displayed. it cannot be set. note: the monitor value is only displayed. it cannot be set. output 1 (out1) on count monitor value output 2 (out2) on count monitor value (9999 1000 times) (0 1000 times) (9999 1000 times) (0 1000 times) (mv) (smp) (99.999) (1.000) (0.001) the characters displayed in reverse video are the default settings. smp mv power on run mode step2 change to function setting mode. 3 s min. *2 3 s min. *1  set the decimal point position using the u key. *1 if the mode is switched to the function setting mode during operation, operation will continue. *2 changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. also, when settings are changed, the counter is reset (measured values initialized and output turned off) on returning to run mode. function setting mode averaging method (augt) prescale value (pscl) decimal point position (dp) (no decimal point) (one digit after decimal point) (two digits after decimal point) (three digits after decimal point)  set each digit using the individual u key.  set the averaging method using the u key. note: not displayed in amd-compatible mode. for details on operations in run mode, refer to page page 47.
h7cx-r @ -n 45 explanation of functions basic functions input mode the mode can be switched between tachometer mode and amd- compatible mode. tachometer mode use this mode to measure the pulse frequency (hz). amd-compatible mode use this mode to measure the pulse cycle (s). counting speed set the maximum counting speed (30 hz /10 khz) for input. if contacts are used for input signals, se t the counting speed to 30 hz. processing to eliminate chattering is performed for this setting. output mode set the output method for control output based on the comparison value. upper and lower limit (hi-lo), area (area), upper limit (hi), and lower limit (lo) can be set. for the h7cx-rw @ , the upper limit (hi- hi) and lower limit (lo-lo) can be set. (for details on the operation of the output modes, refer to output mode settings on page page 49.) averaging method ( avgt ) simple averaging or a moving average can be selected for the averaging method. with a moving average, the average measurement value is displayed every sampling cycle or pulse cycle, in contrast to simple averaging, for which the average value is displayed for the set number of samples. number of averaging times flickering display and output c hattering can be prevented using average processing. average proces sing can be set to one of four levels: no average processing, 2 times (i.e., the average of 2 measurement values), 4 times, or 8 times. for a measurement frequency of 5 hz or higher using a tachometer, the average will be equal to the samp ling cycle (200 ms) multiplied by the averaging setting (i.e., the number of times). for less than 5 hz, the frequency will be measured when the input pulse comes. average processing pr oduces a stable display even for fluctuating input signals. set the optimum number of times for the application. if amd-compatible mode is used, the measurement cycle will be measured when the input pulse is received. the output will change, however, when the comparison val ue is exceeded even if averaging is enabled. npn/pnp input mode select either npn input (no-vo ltage input) or pnp input (voltage input) as the input format. when usi ng a two-wire sensor, select npn input. the same setting is used for all external inputs. for details on input connections, refer to input connections on page page 40. advanced functions decimal point position ( dp ) decide the decimal point positi on for the measurement value and comparison value. prescale value ( psc l) it is possible to display the rate of rotation or the speed of a device or machine to which the h7cx is mount ed by converting input pulses to a desired unit. if the default prescaling value (1 ,000) is used, the input frequency (hz) will be displayed. the relationship between display and input is determined by the following equation. set the prescale value according to the unit to be displayed. displayed value = f f: input pulse frequency (number of pulses in 1 second) : prescale value (1) displaying rotation rate n: number of pulses per revolution example: in order to display the rate of rotation for a machine that outputs 5 pulses per revolution in the form @@ . @ rpm: 1. set the decimal point position to 1 decimal places. 2. using the formula, set the prescale value ( ) to 1/n 60 = 60/5 = 12. (2) displaying speed n: number of pulses per revolution d: diameter of rotating body (m) d: circumference (m)  observe the following points when setting a prescale value. set the set value to a value less than {maximum countable value ? prescale value}. example: if the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 ? 1.25). if the set value is set to a value gr eater than this, output will not turn on. auto-zero time ( auto0 ) it is possible to make the settings so that the frequency will be force- set to 0 if there is no pulse for a s pecified period of time. this time is called the auto-zero time. cycle (s) display unit prescale value ( ) rpm 1/n 60 rps 1/n display unit prescale value ( ) m/min d 1/n 60 m/s d 1/n d: diameter of rotating body (m) note: if the prescale value setting is incorrect, a counting error will occur. check that the settings are correct before using this function. note: set the auto-zero time to a time slightly longer than the estimated interval between input pulses. it will not be possible to make accurate measurements if the auto-zero time is set to a time shorte r than the input pulse cycle. setting a time that is too long may also result in problems, such as a time-lag between rotation stopping and the alarm turning on.
46 h7cx-r @ -n startup time ( stmr ) in order to prevent undesired output resulting from unstable input immediately after the power supply is turned on, measurement can be prohibited for a set time at startup. it can also be used to stop measurement and disable output until the rotating body reaches the normal rate of rotation, after the power supply to the h7cx and rotating body are turned on at the same time. peak/bottom hold enabled ( dhld ) this function records the peak and bottom (i.e., minimum) values after counting starts (after turnin g on the power supply or changing the configuration selecti on mode or function setting). the peak value is also held when the power supply is interrupted. output hysteresis ( hys ) this setting can be used to prevent output chattering if the measurement value fluctuates slightly near the set value. in thachometer mode, the measurem ent value after prescaling is set. output off delay ( offd ) this function delays the timing for turning off comparative output by a certain time. the on time can be held for the set time if the comparative result changes in a short time. operation will continue and outputs will not change while holding the value. set value upper limit ( sl-h ) set the upper limit for the set value when it is set in run mode. key protect level ( ypt ) set the key protect level. refer to key protect level on page page 48. output on count alarm set value ( on-a ) set the alarm value for the output on count. the limit can be set to between 0 1000 (0 times) and 9999 1000 (9,999,000 times). only the underlined values are set. the alarm will be disabled if 0 is set. if the total on count of the output exceeds the alarm set value, e3 will be displayed on the timer to indicate that the output on count alarm value was exceeded. refer to self-diagnostic function on page page 48 for information on the e3 display. on count alarm set values for outputs 1 and 2 (out1 and out2) ( on1a and on2a ) set the on count alarm values for the outputs 1 and 2. the limit can be set to between 0 1000 (0 times) and 9999 1000 (9,999,000 times). only the underlined values are set. the alarm will be disabled if 0 is set. if the total on count of instantaneous output 1 or 2 exceeds the alarm set value, e3 will be displayed on the timer to indicate that the output on count alarm value was exceeded. refer to self-diagnostic function on page page 48 for information on the e3 display. output on count monitor value ( on-c ) the monitor value is only displayed. it cannot be set. the output on count will be 1,000 times the displayed value. on count monitor values for outputs 1 and 2 (out1 and out2) ( on1c and on2c ) the monitor value for output 1 or 2 is only displayed. it cannot be set. the output on count will be 1,000 times the displayed value. startup time display time comparison value (lower limit) output (lower limit) power supply outx1 outy2 display value comparison value 2 hysteresis hysteresis comparison value 1 set the hysteresis for when the output turns off.
h7cx-r @ -n 47 operation in run mode output mode: hi or lo output mode: hi-lo or area h7cx-r11 @ -n h7cx-r11w @ -n displayed for models other than ?-w? models displayed for ?-w? models measurement value measurement value comparison value bottom hold value peak hold value bottom hold value 1 peak hold value 2 bottom hold value 2 peak hold value 1 measurement value measurement value comparison value 1 measurement value comparison value 2 measurement value 1 measurement value 2 comparison value 1 comparison value 2  set each digit using the individual u keys.  measurement value displays the currently measured value.  comparison value, comparison value 1, and comparison value 2 set the comparison value, comparison value 1, and comparison value 2. the measurement value is compared to comparison value, comparison value 1, and comparison value 2 and an output is made according to the selected output mode. *1 *1 peak/bottom hold enabled  peak/bottom hold value the peak (maximum) and bottom (minimum) values are displayed after counting starts.  peak/bottom hold value 2 peaks (maximums) 1 and 2 and bottoms (minimums) 1 and 2 are displayed after counting starts. *1 note: the held values will be initialized when the hold key or reset 1 input is turned off while peak/bottom hold values 1 and 2 are being displayed.(the reset 2 input operates in the same way if the input mode is set to 2-input mode.)
48 h7cx-r @ -n key protect level when the key-protect switch is set to on, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (kp-1 to kp-7). the key protect level is set in the function setting mode. the key protect indicator is lit w hen the key-protect switch is on. * changing mode to dip switch monito r mode or function setting mode. self-diagnostic function the following displays will appear if an error occurs. *1. this includes times when the life of the eeprom has expired. *2. occurs when the measurement value reaches 999,999. *3. display flashes (1-second cycles). *4. the normal display and e3 will appear alternately. when the hold key is pressed, e3 will not be displayed even if the alarm set value is exceeded. (monitoring is possible, howev er, because the counter will cont inue without clearing the output on count.) level meaning details changing mode* switching display during operation hold key up key kp-1 (default setting) invalid valid valid valid kp-2 invalid valid invalid valid kp-3 invalid valid valid invalid kp-4 invalid valid invalid invalid kp-5 invalid invalid invalid invalid kp-6 invalid invalid valid valid kp-7 invalid invalid invalid valid main display sub-display error output status correction method set value after reset ffffff *3 no change measurement value overflow*2 no change measurement value 999999 no change e1 not lit cpu off either press the hold key or reset the power supply. no change e2 not lit memory error (ram) off turn on the power again. no change e2 sum memory error (eep)*1 off hold key factory setting e3 *4 no change output counter overflow no change hold key no change key protect indicator *factory-set to off on (enable) off (disable) *
h7cx-r @ -n 49 output mode settings models other than h7cx-r11w @ in tachometer mode mode ls other than h7cx-r11w @ in amd-compatible mode note: if time ?a? is exceeded during operation, the output will turn on. if time ?b? is exceeded during operation, the output will turn off. (if average processing is enabled, the output operation will be perfor med when the time is exceeded once.) h7cx-r11w @ output mode setting operation upper and lower limit on condition: measurement value comparison value 1 or measurement value comparison value 2 note: when comparison value 1 comparison value 2, the output isalways on regardless of the comparison value. area upper limit on condition: measurement value comparison value lower limit on condition: measurement value comparison value out measurement value comparison value 2 (upper-limit) comparison value 1 (lower-limit) condi- tion comparison value 1 comparison value 2 comparison value 1 > comparison value 2 on con- dition comparison value 1 measurement value comparison value 2 comparison value 2 measurement value comparison value 1 out measurement value comparison value 2 comparison value 1 out comparison value (upper-limit) measurement value out measurement value comparison value (lower-limit) output mode setting operation upper and lower limit on condition: measurement value < comparison value 1 or measurement value comparison value 2 note: when comparison value 1 comparison value 2, the output isalways on regardless of the comparison value. area upper limit on condition: measurement value comparison value lower limit on condition: measurement value < comparison value out measurement value comparison value 2 (upper-limit) comparison value 1 (lower-limit) a condi- tion comparison value 1 comparison value 2 comparison value 1 > comparison value 2 on con- dition comparison value 1 measurement value < comparison value 2 comparison value 2 measurement value < comparison value 1 out measurement value comparison value 2 comparison value 1 b a out comparison value (upper-limit) measurement value b measurement value comparison value (lower-limit) out output mode setting operation upper limit (hi) lower limit (lo) out1 cp1 display value comparison value 1 out2 cp2 display value comparison value 2 on condition for output 1: cp1 present value (display value) comparison value 1 on condition for output 2: cp2 present value (display value) comparison value 2 output 1 output 2 out1 cp1 display value comparison value 1 out2 cp2 display value comparison value 2 on condition for output 1: cp1 present value (display value) comparison value 1 on condition for output 2: cp2 present value (display value) comparison value 2 output 1 output 2
50 h7cx-r @ -n precautions for the h7cx-r in upper and lower limit output mode, if the comparis on value setting is such that comparison value 1 comparison value 2, the output will always be on. hold function the measurement value (display value) and output are sustained while the hold input is on. note: the output will maintain the current status when the hold key is pressed. example: * the h7cx-r11w @ -n does not have a hold input. operation in dip sw itch monitor mode the h7cx-r is also equipped with a dip switch monitor function, a convenient function that enables the settings of the dip swit ch pins to be confirmed using the front display. output mode setting operation lower limit out display value hold input* (hold key) comparison value (lower limit) sustained display value sustained output actual input convenient : measurement stopped : measurement possible 1 1 + key key 1 s min. power on dip switch monitor run mode dip switch monitor mode * ?indicates that dip switch pin 8 is on. ?indicates that dip switch pin 7 is off. ?indicates that dip switch pin 6 is on. ?indicates that dip switch pin 5 is off. ?indicates that dip switch pin 4 is on. ?indicates that dip switch pin 3 is off. ?indicates that dip switch pin 2 is on. ?indicates that dip switch pin 1 is off. example off on 12345678 the status of the dip switch pins (1 to 8) can be confirmed using the u key. * when the mode is changed to dip switch monitor, the measurement value is reset, outputs turns off, and measuring stops. note: to change the mode to dip switch monitor mode, press the key for 1 s min. with the key held down. the mode will not change if the key is pressed first. 1 1
h7cx-r @ -n 51 precautions on replacing the amd-s terminal arrangement and wiring connections note: 1. wiring must be changed from an 8-pin socket to an 11-pin socket. 2. take into consideration the length of the wires and the terminal numbers. 3. order the p2cf-11connecting socket separately. setting procedure perform the following settings to ac hieve the functions of the amd-s using the h7cx-r11-n. dip switch settings note: the characters displayed in reverse video are the default settings. * refer to page page 43 for information on dip switch settings. operation key settings note: the characters displayed in reverse video are the default settings. characteristics * when set to amd mode. the h7cx-r11-n is the recommended model for replacing the amd-s- series motion detector. refer to the following precautions befo re replacing the amd-s. amd-s h7cx-r11-n 3 4 5 6 2 1 8 7 sensor tc ta relay output 100/110 vac (200/220 vac) tb 8pfa black (white) brown (red) blue (black)  connection sockets: 8pfa 5 4 6 7 8 2 3 1 11 10 9 hold hold tb ta relay output 100 to 240 vac tc p2cf-11 black (white) brown (red) blue (black) sensor  connection sockets: p2cf-11 model amd-s h7cx-r11-n item dip switch pin status * set value measuring ranges 0.01 to 0.1 s (amd-s @ 1), 0.1 to 1 s (amd- s @ 2), 1 to 10 s (amd-s @ 3) set dip switch pin 1 to on for amd-compatible mode. 1 ms 10 ms output mode rotation increase detection (amd-su @ ) rotation decrease detection (amd-sl @ ) average process- ing none input mode voltage input off on 12345678 on on off on amd compatible amd compatible 10 ms 1 ms counting speed / minimum input signal width input mode pin 2 pin 1 off on 12345678 lower limit off on 12345678 upper limit off on 12345678 off off on 12345678 pnp model amd-s h7cx-r11-n item parameter s setting range set value startup time fixed (0.1 to 10 s) model amd-s h7cx-r11-n item supply voltage ? 100 to 110 vac ? 200 to 220 vac ? 100 to 240 vac input method voltage input (high: 4 to 14 v, low: 0 to 1 v) no-voltage input/voltage input (high: 4.5 to 30 v, low: 0 to 2 v) external pow- er supply 12 vdc 1 v, 12 ma 12 vdc ( 10%), 100 ma relay output 5 a at 200 vac (resistive load) 3 a at 250 vac/30 vdc (resistive load) output mode rotation increase (amd- su @ ) rotation decrease (amd- sl @ ) hi-lo, area, hi-hi, lo-lo (set using dip switch.) setting meth- od input pulse interval (s) in put pulse interval (s) * detection rota- tion rate range 6 to 6,000 rpm (for 1 pulse/rotation) 0.00006 to 20,000 rpm * (for 1 pulse/rotation) startup time always from 0.1 to 10 s (always 10 s if not specified.) setting range: 0.0 to 99.9 s life expectan- cy output relay electrical operations of 500,000 min. output relay electrical operations of 100,000 min. memory back- up none eeprom (overwrites: 100,000 times min.) stmr (stmr) (99.9 s) (0.0 s)
h7cx- @ -n 52 safety precautions for all h7cx series (common) do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. doing so may occasionally result in electric shock, fire, or malfunction. minor injury due to explosion may occasionally occur. do not use the counter where subject to flammable or explosive gas. fire may occasionally occur. tighten the terminal screws to the rated torque. h7cx terminals: 6.55 to 7.97 lb-in (0.74 to 0.90 nm) p2cf socket terminals: 4.4 lb-in (0.5 nm) minor injury due to electric shock may occasionally occur. do not touch any of the terminals while power is being supplied. be sure to mount the terminal cover after wiring. the life expectancy of the output relay varies considerably according to its usage. use the output relay within its rated load and electrical life expectancy. if the output relay is used beyond its life expectancy, its contacts may become fused or there may be a risk of fire. also, be sure that the load current does not exceed the rated load current and when using a heater, be sure to use a thermal switch in the load circuit. minor electric shock, fire, or malfunction may occasionally occur. do not disassemble, modify, or repair the counter or touch internal components.  the panel surface of the h7cx-a/- r is water-resistant (conforming to nema4, ip66, ul type 4x (i ndoor use only). to protect the internal circuits from water penetration through the space between the h7cx and operating panel, wate rproof packing is included. attach the y92f-30 adapter with sufficient pressure with the reinforcing screws so that water does not penetrate the panel.  when mounting the counter to a panel, tighten the two mounting screws alternately, a little at a ti me, so as to keep them at an equal tightness. if the panel screws are tightened unequally, water may enter the panel.  store the counter at the specified temperature. if the counter has been stored at a temperature of less than ? 10 c, allow the counter to stand at room temperature for at least 3 hours before use.  mounting the counter side-by -side may reduce the life expectancies of internal components.  use the counter within the specified ranges for the ambient operating temperature and humidity.  do not use in the following locations:  locations subject to sudden or extreme changes in temperature.  locations where high humidity may result in condensation.  do not use the counter outside of the rated ranges for vibration, shock, water exposure, and oil exposure.  do not use this counter in dusty environments, in locations where corrosive gasses are present, or in locations subject to direct sunlight.  install the counter well away from any sources of static electricity, such as pipes transporting moldi ng materials, powders, or liquids.  internal elements may be destroyed if a voltage outside the rated voltage range is applied.  be sure that polarity is co rrect when wiring the terminals.  separate the counter from sources of noise, such as devices with input signals from power lines carrying noise, and wiring for i/o signals.  do not connect more than two crimp terminals to the same terminal.  up to two wires of the same size and type can be inserted into a single terminals.  use the specified wires for wiring. applicable wires: awg 18 to awg 22, solid or twisted, copper  install a switch or circuit brea ker that allows the operator to immediately turn off the power, and label it to clearly indicate its function.  when the counter is operated with no-voltage input (npn input), approximately 14 v is output from th e input terminals. use a sensor that contains a diode.  use a switch, relay, or other cont act so that the rated power supply voltage will be reached within 0.1 seconds. if the power supply voltage is not reached quickly enough, the counter may malfunction or outputs may be unstable.  use a switch, relay, or other contact to turn the power supply off instantaneously. outputs may malfunction and memory errors may occur if the power supply voltage is decreased gradually.  when changing the set value during operation, because the h7cx uses a constant read-in system, out put will turn on if the set value is equal to the present value.  when changing the comparison value during operation, because the h7cx uses a constant read-in system, the output status will change if the comparison value is changed to a value on the other side of the present value.  if the set value and present value are both 0, the output will turn on for the default setting. the output will turn off during a reset operation.  when the power is turned on using the factory settings, the output will turn on after 999.9 s if no pulses are received as count input.  do not use organic solvents (such as paint thinners or benzine), strong alkali, or strong acids. they will damage the external finish.  confirm that indications are wo rking normally, including the backlight led, and lcd. the indi cator leds, lcd, and resin parts may deteriorate more quickly depending on the application environment, preventing normal i ndications. periodic inspection and replacement are required.  the waterproof packing may deteriorate, shrink, or harden depending on the application envir onment. periodic inspection and replacement are required. caution precautions for safe use 0.5 to 1 mm it is recommended that the space between the screw head and the adapter be 0.5 to 1 mm. input 0 v sensor diode
h7cx- @ -n 53  h7cx models with a 12 to 24-vdc power supply use a transformer-free power supply method in which the power supply terminals are not isolated from t he signal input terminals. if a non- isolating dc power supply is used, unwanted current paths may occasionally burn or destroy internal components depending on the wiring. always check the wiring sufficiently before use.  an inrush current of approx. 10 a will flow for a short time when the power supply is turned on. if the capacity of the power supply is not sufficient, the counter may not start. be sure to use a power supply with sufficient capacity.  maintain voltage fluctuations in the power supply within the specified operating voltage range.  when turning the power on and off, input signal reception is possible, unstable, or impossible as shown in the diagram below.  inrush current generated by turni ng on or off the power supply may deteriorate contacts on the pow er supply circuit. turn on or off to a device with the rated current of more than 10 a.  the capacity of the external pow er supply is 100 ma at 12 v. when using a 24 vac/12 to 24 vdc power supply, reduce the load with the power supply voltage, as show n in the following diagram (dc power supplies only).  if the prescale value setting is in correct, a counting error will occur. check that the settings are corre ct before using this function.  make sure that all settings are appropriate for the application. unexpected operation resulting in property damage or accidents may occur if the settings are not appropriate.  do not leave the counter for long periods at a high temperature with output current in the on state. doing so may result in the premature deterioration of inter nal components (e.g., electrolytic capacitors).  eeprom is used as backup memory when the power is interrupted. the write life of the eeprom is 100,000 writes. the eeprom is written at the following times:  when the power supply is turned off  when switching from configuration selection mode or function setting mode to run mode  dispose of the product according to local ordinances as they apply.  attach the front panel when using the counter. the tabs in the middle of each of four sides secu re the front panel to the main body. to remove the panel, widen the four tabs and pull the panel toward you. to mount the panel, fit all four tabs correctly into the grooves on the main body.  when conforming to emc standards, refer to the information provided in this datasheet for c able selection and other conditions.  this is a class a product. in resi dential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. h7cx-a @ -n: basic insulation is provided between power supply and input terminals, between power supply and output terminals, and between input and output terminals. (however, no insulation is provided between the power suppl y and input terminals for the h7cx-a @ d-n.) h7cx-r @ -n: basic insulation is provided between power supply and input terminals and between input and output terminals.  when double insulation or reinforced insulation is required, apply double insulation or reinforced insulation as defined in iec 60664 that is suitable for the maximu m operating voltage with clearances or solid insulation.  connect the input and output termi nals to devices that do not have any exposed charged parts. precautions for correct use input impossible 200 ms 5 ms 0 to 90 ms 0 to 1 s possible unstable unstable impossible power supply on off power supply voltage (vdc) 10.8 15 100 20 load current (ma) conformance to en/iec standards ta b s grooves
54 memo
warranty and application considerations read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have any questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular p urpose of the products. any buyer or user acknowledges that the buyer or user alone has de termined that the product s will suitably meet the requirements of their intended use. om ron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indire ct, or consequential damages, loss of profits, or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, neglige nce, or strict liability. in no event shall the responsibility of omron for any act exce ed the individual price of the pro duct on which liability is asse rted. in no event shall omron be responsible for wa rranty, repair, or other claims regarding the products unless omron's analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it wil l be used. know and observe all prohibitions of use applicable to this product. never use the products for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron products are properly rated and installed for th e intended use within the overall equipment or system. disclaimers performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron's test conditi ons, and the users must correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability . change in specifications product specifications and accessories may be changed at an y time based on improvements and other reasons. consult with your omron representative at any time to confir m actual specifications of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used fo r manufacturing purposes, even when tolerances are shown. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0. 03937. to convert grams into ounces, multiply by 0.03527.
authorized distributor: in the interest of product improvement, specifications are subject to change without notice. cat. no. m079-e1-01 printed in japan 0709 omron corporation industrial automation company regional headquarters omron europe b.v. wegalaan 67-69-2132 jd hoofddorp the netherlands tel: (31)2356-81-300/fax: (31)2356-81-388 omron electronics llc one commerce drive schaumburg, il 60173-5302 u.s.a. tel: (1) 847-843-7900/fax: (1) 847-843-7787 omron asia pacific pte. ltd. no. 438a alexandra road # 05-05/08 (lobby 2), alexandra technopark, singapore 119967 tel: (65) 6835-3011/fax: (65) 6835-2711 omron (china) co., ltd. room 2211, bank of china tower, 200 yin cheng zhong road, pudong new area, shanghai, 200120, china tel: (86) 21-5037-2222/fax: (86) 21-5037-2200 omron industrial automation global: www.ia.omron.com control devices division h.q. environment business department 2-2-1 nishikusatsu, kusatsu-shi, shiga, 525-0035 japan tel: (81) 77-565-6501/fax: (81) 77-565-7146 ? omron corporation 2009 all rights reserved.


▲Up To Search▲   

 
Price & Availability of H7CX-AW-N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X